8345
Part | Datasheet |
---|---|
![]() |
8345-B02A-T3M2-DB1B1C-X8345-S01HW102M-15A (pdf) |
Related Parts | Information |
---|---|
![]() |
8345-B02A-L6T2-DB1B1C-30A |
![]() |
8345-B24A-T3K2-DB1B2B-16A |
![]() |
8345-B03A-V3M0-DB1B1C-125A |
![]() |
8345-C01A-R0M1-DB1B2B-50A |
![]() |
8345-F01Z-R0M1-DB1B1B-125A |
![]() |
8345-F01Z-R0M1-DB1B2B-125A |
![]() |
8345-F01A-V3T1-DB1B1B-125A |
![]() |
8345-E01A-V3T1-DB1B1B-125A |
![]() |
8345-F02A-U3K2-DB1B1C-100A |
![]() |
8345-B02A-T3M2-DB1B1C-X8345-S01HW102M-30A |
![]() |
8345-F02A-P0M1-DB1B1A-X8345-S02KW102M-2A |
![]() |
8345-F01Z-R0M1-DB1B2B-100A |
![]() |
8345-F01Z-R0M1-DB1B2B-10A |
![]() |
8345-F01A-V3T1-DB1B1B-100A |
![]() |
8345-F02A-P0M1-DB1B1A-X8345-S02KW202M-2A |
![]() |
8345-B03A-L6M1-DB1B1B-50A |
![]() |
8345-B23A-L6T2-DB1B2B-30A |
![]() |
8345-B22B-T9M0-DB1B1B-30A |
![]() |
8345-B02B-T3M1-DB1B1B-50A |
![]() |
8345-B02A-S3M0-DB2B2C-15A |
![]() |
8345-C12A-S3M2-DB1B1C-10A |
![]() |
8345-C12A-S3M2-DB1B1C-2A |
![]() |
8345-B22A-V3M2-DB1B1B-10A |
![]() |
8345-B22A-V3M2-DB1B1B-5A |
![]() |
8345-C02A-U3M1-DB1B2B-100A |
![]() |
8345-B02A-V3M0-DB1B1C-50A |
![]() |
8345-B22B-V3F2-DB1B1B-50A |
![]() |
8345-C12A-S3M2-DB1B1C-15A |
![]() |
8345-B22A-V3M2-DB1B2B-125A |
![]() |
8345-B03A-V3M2-DB1B1C-50A |
![]() |
8345-F23A-S3M2-DB1B1B-60A |
![]() |
8345-F23B-S3M2-DB1B1B-60A |
![]() |
8345-B03A-V3K2-DB1B1C-75A |
![]() |
8345-B23A-T3M0-DB1B1B-30A |
![]() |
8345-B03A-V3K2-DB1B1C-100A |
![]() |
8345-E03B-S3T2-DB1B1C-X8345-S02HW102M-20A |
![]() |
8345-F23A-S3M2-DB1B1B-40A |
![]() |
8345-B03A-T3T2-DB2B1C-40A |
![]() |
8345-E03B-S3M2-DB1B1C-X8345-S02HW102M-10A |
![]() |
8345-B03A-T3M1-DB1B1B-50A |
![]() |
8345-C23A-U3M2-DB1A1B-20A |
PDF Datasheet Preview |
---|
Magnetic and Hydraulic-Magnetic Circuit Breaker Single or multipole hydraulic-magnetic circuit breakers with trip-freemechanism and toggle actuation. A choice of switching characteristics ensures suitability for a wide range of applications. Industry standard dimensions and panel mounting. Auxiliary contacts optional. Low temperature sensitivity at rated load. Approved to CBE standard EN 60934 IEC 60934 S-type HM CBE. In the business fields Communication and Transport power supplies, switchgear, instrumentation and process control engineering. 1 pole 8345 2 pole Standard current ratings and typical internal resistance values Technical data Current Trip curves and internal resistance per pole rating A F1 K1, M1, T1, K2, M2, T2 Voltage rating 3 AC 415 V AC 277/480 V AC 120/240 V AC 240 V DC 80 V, 452 100 376 94 Current rating range A single and multipole A single pole, two poles connected in parallel higher ratings upon request Auxiliary circuit AC 240 V/DC 28 V 6 A 0,048 DC 65 V 1 A DC 80 V A Typical life 10,000 operations at 1 x IN Ambient temperature -40 °C...+85 °C -40 °F Insulation co-ordination IEC 60664 kV/2 reinforced insulation in operating area Dielectric strength test voltage operating area pole to pole main to auxiliary circuit switching to trip circuit AC 3000 V AC 1500 V AC 1500 V AC 1500 V Insulation resistance Degree of protection IEC 60529 > 100 DC 500 V operating area IP40 terminal area IP00 Vibration Interrupting capacity to EN 60934, UL 489 and UL 1077 IEC 60934 test series E Ordering information Type No. 8345 Mounting B flange mounting, with rectangular aperture with mounting nut 6-32 UNC C flange mounting, with rectangular aperture with mounting nut M3 E flange mounting, with round aperture with mounting nut 6-32 UNC F flange mounting, with round aperture with mounting nut M3 Configuration 0 without barrier 1 with small barrier 2 with large barrier required for UL 489 multipole Number of poles 0 single pole unprotected 1 single pole protected 2 two pole protected 3 three pole protected 4 four pole protected P single pole protected, two poles connected in prallel Actuator configuration A all poles with standard toggle B reduced number of standard toggles Z without actuator Terminal design K screw terminals M4 35 A L screw terminals M5 50 A M solder terminals 75 A P blade terminals 35 A R round connectors 6 mm S stud terminals M5 A T stud terminals 10-32 UNF-3A 60 A U stud terminals M6 V stud terminals 1/4-20UNC-3A 125 A Terminal hardware 0 without 3 with washer and nut 6 Phillips screws Characteristic curve F1 instantaneous trip DC x IN F2 instantaneous trip AC x IN K1 short delay DC K2 short delay AC M0 medium delay AC/DC M1 medium delay DC 8345 - C 0 1 A - U 3 M1 - D B1 A1 B - 60 A - ordering example Remote trip coil available to special order! Ordering information for auxiliary contact module Type number X8345 Module S auxiliary contact module Auxiliary contacts 01 in all poles 02 in pole 1 only 03 in poles 1 + 3 only 04 in pole 2 only Auxiliary contact version H auxiliary contacts standard asymmetrical terminals not for UL 489 K auxiliary contacts symmetrical terminals Auxiliary contact function W1 1 changeover Terminal design 02 microswitch with blade terminals DIN 46244-A2,8-0,5 M mounted to base unit X8345 - S 01 H W1 02 M ordering example ¤ Germany 0 91 87 10-0 - USA 847 827-7600 - UK 01296 420336 - Issue G Magnetic and Hydraulic-Magnetic Circuit Breaker Dimensions Installation drawing Mounting version B/C Flange mounting rectangular aperture 48 Cut-out dimensions: 1 pole LOAD LINE number of poles 1 to 4 pole 1 2 3 4 mounting thread M3 or 6-32 mounting depth mm/.165 in. 19 multipole operating area reinforced insulation mounting terminal area area LINE LOAD Mounting version E/F Flange mounting round aperture number of poles 1 to 4 pole 1 2 3 4 mounting thread M3 or 6-32 mounting depth mm/.165 in. Actuator configuration A 1 toggle per pole LINE ON OFF LOAD Cut-out dimensions: 1 pole 6-32UNC M3 6-32UNC 4 pole 57 38 B reduced number of toggles per unit Z without toggles Issue G This is a metric design and millimeter dimensions take precedence mm inch ¤ Germany 0 91 87 10-0 - USA 847 827-7600 - UK 01296 420336 - Magnetic and Hydraulic-Magnetic Circuit Breaker All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. ¤ Germany 0 91 87 10-0 - USA 847 827-7600 - UK 01296 420336 - Issue G |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 8345-B02A-T3M2-DB1B1C-X8345-S01HW102M-15A Datasheet file may be downloaded here without warranties.