4220-T110-K0F1-H000-A-5A-V

4220-T110-K0F1-H000-A-5A-V Datasheet


Thermal-Magnetic Circuit Breaker 4220-T...

Part Datasheet
4220-T110-K0F1-H000-A-5A-V 4220-T110-K0F1-H000-A-5A-V 4220-T110-K0F1-H000-A-5A-V (pdf)
Related Parts Information
4220-T110-K0M1-H121-A-4A-V 4220-T110-K0M1-H121-A-4A-V 4220-T110-K0M1-H121-A-4A-V
4220-T110-K0M1-H000-A-1.5A-V 4220-T110-K0M1-H000-A-1.5A-V 4220-T110-K0M1-H000-A-1.5A-V
4220-T110-K0M1-H121-A-0.1A-V 4220-T110-K0M1-H121-A-0.1A-V 4220-T110-K0M1-H121-A-0.1A-V
4220-T110-K0M1-H121-A-0.3A-V 4220-T110-K0M1-H121-A-0.3A-V 4220-T110-K0M1-H121-A-0.3A-V
4220-T110-K0M1-H121-A-0.5A-V 4220-T110-K0M1-H121-A-0.5A-V 4220-T110-K0M1-H121-A-0.5A-V
4220-T110-K0M1-H121-A-0.8A-V 4220-T110-K0M1-H121-A-0.8A-V 4220-T110-K0M1-H121-A-0.8A-V
4220-T110-K0M1-H121-A-1.5A-V 4220-T110-K0M1-H121-A-1.5A-V 4220-T110-K0M1-H121-A-1.5A-V
4220-T110-K0M1-H121-A-10A 4220-T110-K0M1-H121-A-10A 4220-T110-K0M1-H121-A-10A
4220-T110-K0M1-H121-A-3A 4220-T110-K0M1-H121-A-3A 4220-T110-K0M1-H121-A-3A
4220-T110-K0M1-H121-A-1A-V 4220-T110-K0M1-H121-A-1A-V 4220-T110-K0M1-H121-A-1A-V
PDF Datasheet Preview
Thermal-Magnetic Circuit Breaker 4220-T...

Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 5 kA , EN/IEC 60934 6kA and UL 1077 5 kA . With toggle actuation, positively trip-free mechanism, a choice of characteristic curves and a wide range of current ratings in finely graded steps from A through 32 A. Auxiliary contacts make or break contacts are optionally available. Track-mountable design, width only mm. Ease of wiring by means of an integral busbar concept line entry busbar LINE+ and signal busbars/signal jumpers.

US patent number US 8,098,119 B2 Modularity US patent number US 7,978,033 B2 Release Mechanism US patent number US 7,834,290 B2 Quenching Chamber
4220-T...
single pole
three pole

Protection of power supplies, equipment and cables in centralised control systems and in decentralised installations serving automation, petro-chemical, power plant, steel industry and similar industrial applications.
Ordering Information

Type number 4220 thermal-magnetic high performance circuit breaker

Mounting T1 track-mounting Number of poles 1 single pole 2 double pole 3 three pole Additional feature 0 without actuator guard 1 with actuator guard Main terminals K0 screw terminals 16 mm2 / 10 mm2 Characteristic curve F1 thermal-magnetic, extremely fast, DC F2 thermal-magnetic, fast, AC/DC M1 thermal-magnetic, medium delay, AC/DC T1 thermal-magnetic, long delay, AC/DC Auxiliary contacts H0 without H1 with auxiliary contacts in all poles H2 with auxiliary contacts only in pole 1 2-pole plus H3 with auxiliary contacts only in poles 1+3-pole plus H4 with auxiliary contacts only in pole 2 3-pole plus H5 with auxiliary contacts only in the last pole H6 with auxiliary contacts only in poles 1+2 3-pole plus Auxiliary contact function 0 without 2 make contact N/O 3 break contact N/C A pole 1 make contact, all other poles break contacts 2-pole plus 1+2 make contacts, other poles break
contacts 3-pole plus C pole 1 break contact, other poles make contacts 2-pole plus Auxiliary contacts terminal design 0 without 1 screw terminals 1 mm2 Voltage rating A AC 277 V or DC 60 V Current rating range A Approval logo optional V UL 489 1-pole
4220 - T1 1 0 - K0 M1- H1 2 1 - A - 10 A -V ordering example

Technical data

For further details please see catalogue section Technical Information

Voltage rating

AC 240 V 3 AC 415 V 50/60 Hz DC 60 V UL AC 120 V AC 277 V 3 AC 415 V DC 60 V

Current rating range

Auxiliary circuit

DC 10 - 30 V, 10 - 500 mA, resistive

Typical life

IEC 60934 AC 240/415 V

AC 240 V:

DC 60 V:

UL 489 AC 120 V:

UL 1077 AC 277/480 V

AC 277 V:

DC 60 V:
1,000 cycles at 1 x IN, ind. load 6,000 cycles at 1 x IN, inductive load 6,000 cycles at 1 x IN, resistive load 6,000 cycles at 1 x IN, inductive load 3,000 cycles at 1 x IN, inductive load 6,000 cycles at 1 x IN, inductive load 6,000 cycles at 1 x IN, resistive load

Ambient temperature
°C °F, T60

Storage temperature
°C °F

Insulation co-ordination IEC 60664 kV / 2
re-inforced insulation in the operating area

Dielectric strength operating area
pole to pole main circuit to auxiliary circuit open main circuit open auxiliary circuit

IEC 60934 test voltage AC 3,000 V reinforced insulation test voltage AC 1,500 V
test voltage AC 1,500 V test voltage AC 1,500 V test voltage AC 250 V

Insulation resistance
> 100 MΩ DC 500 V

Interrupting capacity

Inc PC1 IEC 60934

AC 240 V, AC 240/415 V 6,000 A DC 60 V 6,000 A

Interrupting capacity UL 489

AC 120 V 5,000 A

Interrupting capacity UL 1077

AC 277 V, AC 277/480 V 5,000 A DC 60 V 5,000 A

Protection class IEC 60529
operating area IP30 terminal area IP00

Vibration sinusoidal
± mm 10-57 Hz , 5 g 57-500 Hz test to IEC 60068-2-6, test Fc, 10 frequency cycles/axis

Shock
All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted.
1646
More datasheets: A3964SLB | 3144 | 3130 | B88069X0830B103 | M4513 SL005 | M4513 SL002 | M4513 SL001 | TISP2125F3DR-S | TISP2180F3DR-S | 4220-T110-K0M1-H121-A-4A-V


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 4220-T110-K0F1-H000-A-5A-V Datasheet file may be downloaded here without warranties.