105-P30-H-7A

105-P30-H-7A Datasheet


105

Part Datasheet
105-P30-H-7A 105-P30-H-7A 105-P30-H-7A (pdf)
Related Parts Information
105-P10-H-6A 105-P10-H-6A 105-P10-H-6A
105-P30-H-5A 105-P30-H-5A 105-P30-H-5A
106-M3-P10-2.5A 106-M3-P10-2.5A 106-M3-P10-2.5A
106-M3-P10-5A 106-M3-P10-5A 106-M3-P10-5A
PDF Datasheet Preview
Thermal Overcurrent Circuit Breakers

Miniaturised single pole thermal circuit breaker with push-to-reset tease free, trip-free, snap action mechanism R-type TO CBE to EN Available in versions for PCB or panel mounting, snap-in or threadneck, or as an integral type. Manual release facility optional for type Approved to CBE standard EN 60934 IEC For higher current ratings see type

Motors, transformers, solenoids, printed circuit boards, hand-held machines and appliances, marine applications, caravans.
Ordering information

Technical data

Type No.

PCB mounting type -PR , or integral type -P30/P10
snap-in panel mounting
threadneck panel mounting with hex and knurled nut *
international version
106-M1 as 106 but for standard fuseholder cut-out * double D
106-M2 threadneck panel mounting 3/8-27UNS with collar, hex nut and
knurled nut* US version
106-M3 as 106-M2 but for standard fuseholder cut-out double D

Terminal design

P10 blade terminals A6.3-0.8 QC

P30 blade terminals A2.8-0.8 QC

PR solder terminal pins for PCB mounting type 104 only

PR2 PCB mounting vertical , type 104 only up to 6 A

PR3 PCB mounting vertical , type 104 only

Shunt terminal optional

A3 same as main terminals up to IN 6 A/3 A max. load Manual release facility

H type 105 only

Auxiliary contacts optional

Si51 type 104 only

Current ratings
106-M2 - P30
- - - 5 A = ordering example
The exact part number required can be built up from the table of choices shown above. Ordering references for optional features should be omitted if not required.
* mounting hardware bulk shipped

Packaging quantity 125 pcs

Standard current ratings and typical internal resistance values

Current rating A 1

Internal resistance 285 134
81 22

Current rating A
2 3 4 5 6 7 8 10

Internal resistance

Voltage rating

AC 240 V DC 48 V UL AC 250 V

Current ratings

Auxiliary circuit

A, AC 240 V, DC 28 V

Typical life

A 3,000 operations at 2 x IN
6 A 500 operations at 2 x IN
50 operations at 2 x IN
with -H A 2,000 operations at 1 x IN
200 operations at 1 x IN

Ambient temperature
°C °F T 60

Insulation co-ordination IEC 60664 and 60664 A

Rated impulse

Pollution
withstand voltage
degree
reinforced insulation in operating area

Dielectric strength IEC 60664 and 60664A operating area

Test voltage AC 3,000 V

Insulation resistance
>100 DC 500 V

Interrupting capacity Icn
2 A 6 x IN A 5 x IN

Interrupting capacity UL 1077

UN AC 250 V DC 48 V
2000 A 200 A

Degree of protection IEC 60529/DIN 40050
operating area IP 40 terminal area IP 00

Vibration
All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted.

USA 847 827-7600 - CANADA 905 764-9510

Issue C
More datasheets: FC-13F 32.76800KA-A3 | SRU3009-100Y | SRU3009-1R3Y | SRU3009-220Y | SRU3009-2R2Y | SRU3009-3R3Y | SRU3009-4R7Y | SRU3009-6R8Y | 105-P10-H-6A | 105-P30-H-5A


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 105-P30-H-7A Datasheet file may be downloaded here without warranties.

Datasheet ID: 105-P30-H-7A 510408