AMD-24V080W3CA

AMD-24V080W3CA Datasheet


MODEL AMD-24V080WxyA

Part Datasheet
AMD-24V080W3CA AMD-24V080W3CA AMD-24V080W3CA (pdf)
PDF Datasheet Preview
Switch Mode Power Supply

MODEL AMD-24V080WxyA

Medical Adapter

AMD-24V080WxyA

Features:
• 80Watts Output Power.
• 100-240Vac Universal

Input.
• AC Receptacle with C14

IEC320AC receptacle
• Efficiency > 87%
• No load power consumption
< 0.5W
• Energy star Compliant

Level V
• Low leakage current
• Brownout & Brownout

Recovery
• Medical safety standard
compliant UL6060111/EN60601-1/CSA60601-1
• MTBF > 600,000 Hrs.

The AMD-24V080WxyA is the Medical Adapter from one of the world’s largest power supply manufacturers -Delta. The product offers a regulated output voltage of 24V, along with wide temperature range from 0°C to +40°C and a minimum holdup time of 15ms. The state-of-the-art design is made to withstand medical equipment requirements. The rugged, ultra-compact plastic case with shock and vibration resistants.

The 80 watts Medical power supply provides overvoltage, overload and over temperature protection. Due to the wide input voltage range from 90 to 264Vac Nominal input 100Vac to 240 Vac , the Delta’s medical power supply is worldwide usable. The Input Socket & output connector are made for easy installation.
1/5 3/18/2011

Switch Mode Power Supply

Technical Data

Medical Adapter

AMD-24V080WxyA

Input Data 1 Nominal input voltage wide-range input Voltage range Frequency Max Input Current Inrush current limitation. I2t +25 °C typ. Efficiency at 115VAC and nominal values No load power consumption Mains buffering at nominal load typ. Turn-on time after applying the mains voltage Transient surge voltage protection Input fuse, internal device protection Discharge current to PE Connection Method
80W Medical Adapter
100V-240vac 90V-264vac 47-63 Hz 0.9A max 115 Vac, 0.45A max 230 Vac. 40A 115vac & 80A 230Vac >87% >0.5W 15 msec min 115 Vac 3Sec VARISTOR T AH / 250V < 0.25mA Pluggable

Output Data 2 Nominal output voltage UN / tolerance Setting range of the output voltage Nominal output current IN with convection cooling:-20 to +50°C Max. power dissipation idling/nominal load approx. Ripple/ Noise 20 MHz Line Regulation Load Regulation :

Protection :
24V ± 2% 23.5V-24.5V
3.3A 80W <240mVpp +25 °C +

Exclude output cord + 1% Include output cord + 5% Over current Auto Recovery Over Voltage Auto Recovery Over Temp Latch

Certification/Standards Electrical safety of information technology equipment RoHS Compliant

UR/cUR As per STD UL60601-1/CSA60601-1, CB scheme to EN/IEC60601-1, DEMKO EN60601-1 CE Mark LVD and EMC
2/5 3/18/2011

Switch Mode Power Supply

Medical Adapter

AMD-24V080WxyA

General Data

MTBF

Type of housing

Dimensions W / H / D + mounting rail

Weight

Climatic Data

Ambient temperature Operating

Ambient temperature Storage
More datasheets: AT87F51RC-24AC | AT87F51RC-24PI | 50739160331600F | FDS6894AZ | MBRB1535CT-T | MBRB1530CT-T | MBRB1540CT-T | MBRB1545CT-T | S1D13513B00B200 | S1D13513F01A100


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived AMD-24V080W3CA Datasheet file may be downloaded here without warranties.

Datasheet ID: AMD-24V080W3CA 508482