MODEL AMD-24V060WxyA
Part | Datasheet |
---|---|
![]() |
AMD-24V060W2BA (pdf) |
Related Parts | Information |
---|---|
![]() |
AMD-24V060W3BA |
![]() |
AMD-24V060W3AA |
![]() |
AMD-24V060W2AA |
PDF Datasheet Preview |
---|
Switch Mode Power Supply MODEL AMD-24V060WxyA Medical Adapter AMD-24V060WxyA The AMD-24V060WxyA is the Medical Adapter from one of the world’s largest power supply manufacturers -Delta. The product offers a regulated output voltage of 24V, along with wide temperature range from 0°C to +40°C and a minimum holdup time of 15ms. The state-of-the-art design is made to withstand medical equipment requirements. The rugged, ultra-compact plastic case with shock and vibration resistants. Features: • 60Watts Output Power. • 100-240Vac Universal Input. • AC Receptacle with C8 & C14 option IEC320AC receptacle • Efficiency > 87% • No load power consumption < 0.5W • Energy star Compliant Level V • Low leakage current • Brownout & Brownout Recovery • Medical safety standard compliant UL6060111/EN60601-1/CSA60601-1 • MTBF > 600,000 Hrs. The 60 watts Medical power supply provides overvoltage, overload and over temperature protection. Due to the wide input voltage range from 90 to 264Vac Nominal input 100Vac to 240 Vac , the Delta’s medical power supply is worldwide usable. The Input Socket & output connector are made for easy installation. 1/5 3/18/2011 Switch Mode Power Supply Technical Data Medical Adapter AMD-24V060WxyA Input Data 1 Nominal input voltage wide-range input Voltage range Frequency Max Input Current Inrush current limitation. I2t +25 °C typ. Efficiency at 115VAC and nominal values No load power consumption Mains buffering at nominal load typ. Turn-on time after applying the mains voltage Transient surge voltage protection Input fuse, internal device protection Discharge current to PE Connection Method 60W Medical Adapter 100V-240vac 90V-264vac 47-63 Hz 1.2A max 115 Vac, 0.7A max 230 Vac. 40A 115vac & 80A 230Vac >87% >0.5W 15 msec min 115 Vac 3Sec VARISTOR T AH / 250V < 0.25mA Pluggable Output Data 2 Nominal output voltage UN / tolerance Setting range of the output voltage Nominal output current IN with convection cooling:-20 to +50°C Max. power dissipation idling/nominal load approx. Ripple/ Noise 20 MHz Line Regulation Load Regulation : Protection : 24V ± 2% 23.5V-24.5V 2.5A 60W <240mVpp +25 °C + Exclude output cord + 1% Include output cord + 5% Over current Auto Recovery Over Voltage Latch Over Temp Latch Certification/Standards Electrical safety of information technology equipment RoHS Compliant UR/cUR As per STD UL60601-1/CSA60601-1, CB scheme to EN/IEC60601-1, NEMKO EN60601-1 CE Mark LVD and EMC 2/5 3/18/2011 Switch Mode Power Supply Medical Adapter AMD-24V060WxyA General Data MTBF Type of housing Dimensions W / H / D + mounting rail Weight Climatic Data Ambient temperature Operating Ambient temperature Storage Humidity In conformance with EMC guideline 89/336/EEC and low voltage directive 73/23/EEC EMC electromagnetic compatibility |
More datasheets: 5553002 | 5553004 | 5553005 | 5553010 | 1001932FT-AA10L0100 | 76000842 | 1578 | AMD-24V060W3BA | AMD-24V060W3AA | AMD-24V060W2AA |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived AMD-24V060W2BA Datasheet file may be downloaded here without warranties.