CUS Series
Part | Datasheet |
---|---|
![]() |
CUS8 (pdf) |
Related Parts | Information |
---|---|
![]() |
6204003 |
![]() |
6204004 |
![]() |
6204008 |
![]() |
6204002 |
![]() |
6204009 |
![]() |
6204000 |
![]() |
6204006 |
![]() |
6204005 |
![]() |
6204007 |
![]() |
6204001 |
![]() |
2PDWTP |
![]() |
2PWTP |
![]() |
18835 |
![]() |
18830 |
![]() |
18831 |
![]() |
18836 |
![]() |
18837 |
![]() |
CUS5 |
![]() |
18832 |
![]() |
18821 |
![]() |
CUS16 |
![]() |
18838 |
![]() |
6204100 |
![]() |
6204200 |
![]() |
6204010 |
![]() |
6302000 |
![]() |
6302100 |
![]() |
3PDSWTCP |
![]() |
3PDSWTC |
![]() |
3PSWTC |
![]() |
3PSWT |
![]() |
3PDSWTP |
![]() |
2PSWTC |
![]() |
2PDSWTC |
![]() |
2PDSWSP |
![]() |
2PSWSP |
![]() |
2PDWT |
![]() |
3PDSWSP |
![]() |
3PDSWS |
![]() |
RS2 |
![]() |
CUS12 |
![]() |
RS12 |
![]() |
3PSWS |
![]() |
2PDSWTP |
![]() |
2PSWTP |
![]() |
6504004 |
![]() |
6504000 |
![]() |
6504002 |
![]() |
6504005 |
![]() |
6504006 |
![]() |
6504007 |
![]() |
6504008 |
![]() |
6504001 |
![]() |
2PDSWT |
![]() |
2PSWT |
![]() |
6204110 |
![]() |
6302110 |
![]() |
6302120 |
![]() |
6204130 |
![]() |
2PSWS |
![]() |
2PDSWS |
![]() |
W-7 |
![]() |
SW-9 |
![]() |
W-6 |
![]() |
SW-6 |
![]() |
W-5 |
![]() |
SW-5 |
![]() |
W-82 |
![]() |
W-2 |
![]() |
SW-8 |
![]() |
SW-2 |
![]() |
W-3 |
![]() |
SW-3 |
![]() |
SW-4 |
![]() |
SW-192 VINYL |
![]() |
W-164 |
![]() |
SW-192 |
![]() |
W-4 |
![]() |
W-12 |
![]() |
SW-96 VINYL |
![]() |
W-15 |
![]() |
SW-15 |
![]() |
W-14 |
![]() |
SW-14 |
![]() |
W-13 |
![]() |
SW-7 |
![]() |
SW-13 |
![]() |
W-8 |
![]() |
SW-12 |
![]() |
W-11 |
![]() |
SW-11 |
![]() |
W-10 |
![]() |
SW-10 |
![]() |
W-9 |
![]() |
SW-96 |
![]() |
2PWTCP |
![]() |
2PDWTCP |
![]() |
2PDWTC |
![]() |
3PSWTCP |
![]() |
2PSWTCP |
![]() |
2PDSWTCP |
![]() |
3PSWSP |
![]() |
3PDSWT |
![]() |
3PSWTP |
![]() |
RS16 |
![]() |
RS4 |
![]() |
RS14 |
![]() |
RS15 |
![]() |
RS6 |
PDF Datasheet Preview |
---|
Innovative Engineering Solutions Terminal Blocks Contents Selection Guide 2 BARRIER STYLE TERMINAL BLOCKS ] Single Row SE/SEI 6 32500 8 37000/38000 10 CB/CFT 16 43000 20 GFT/GB 24 Dual Row 1500 28 2000 30 M 34 5600 36 High Voltage/Current Series SW & DSW 38 Series W 40 Types CDM 42 Series 71000 44 Types H & BT 46 Types T & U 48 Types L, O & S 50 RELAY SOCKETS ] Snap-In Socket Assemblies 54 CUS Series CUS8 55 CUS5, CUS12 and CUS16 55 RS Series RS8, RS11 56 RS2, RS4 and RS6 57 RS12 and RS16 58 RS14, RS15 59 Accessories 60 DIN RAIL TERMINAL BLOCKS ] Din Rail Terminal Block Features 62 Multiple Wire Connections 63 Screw Connections Single Level 64 Dual Level Block 68 Screwless Connections Single Level 70 Single-Multi Level 71 Ground Blocks 72 Fuse Blocks 73 Ground Blocks 75 Mounting Rails 77 Accessories 78 Curtis Industries Terminal Block Selection Guide Barrier Style TERMINAL TYPES RATING HOUSING AGENCY Approvals Feed-Thru Fully Insulated Feed Thru Printed Circuit Surface Fully Insulated Voltage Varies with Application see specifications Current Amps Black Phenolic *150°C 302°F Polyphenylene •110°C 230°F Thermoplastic-Poly *140°C 284°F Flammability UL Recognition CSA Certified Series/ Type TERMINAL SPACINGS Center-toCenter Spacing Wire Range Number of Terminals Catalog Page Number SE/SEI 1/4" 6 .35mm 22 to 16 When ordering non-DIN track to a specified size, simply designate model followed by length required, expressed in poles Example SW with space for 24 poles plus two mounting holes becomes stock number SW-24 For standard three and six foot lengths, simply designate model followed by 96 or 192 respectively SW Series or 82/164 W Series Examples SW-96 or SW-192 W-82 or W-164 For DIN track, specify DT and length of track desired in 2 centimeter increments For example, DT-10 designates DIN track 10 centimeters in length Dimensions are ± cm Fuse blocks, knife switches and WH Type terminal assembles are the same width as two-pole W modules and therefore require twice the space of a single pole W Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents Curtis Industries A Division of Powers Holdings, Inc. 1-800-657-0853 41 High Voltage/Current Type CDM 35/64" 13 .86mm Center-to-Center Spacing Features: • Versatile Medium Power Terminal Blocks Designed for surface mount power and control applications requiring a wide range of terminal variations • Sectional Thru-Bolt Construction Available in one thru 50 terminals on 35/64" center-to-center spacing Rated 30A/600V for Type CDM • Durable Break-Resistant Thermoplastic Moldings • Wire Sizes Type CDM features brass terminal bar with two No 10-32 washer-head screws UL recognized for No 22AWG to No 10AWG • Easy Crcuit Identification Design Barrer-type terminals are furnished with a white fiber marking strip • Recognition and Listing Various terminal types are UL recognized and CSA certified Specifications: Center-to-Center Spacing 35/64" 13 .86mm Wire Range CDM UL Recognized for 22AWG to No 10AWG No. of Terminals 1 thru 50 Voltage Rating CSA & UL 600V Tightening Torque 35 in .-lb Current Rating CDM 30 amps, UL and CSA Housing Material Continuous Use Temp UL Index Flammability Rating Water Absorption 24 hrs % wt gain Chemical Resistance Thermoplastic-polyester 130°C 266°F 94V-0 0 Excellent in most environments Breakdown Voltage Terminal - Terminal - Ground CDM 9,600V Typ 10,800V Typ Note Specifications contained herein are subject to change without notice Recognized under the Components Program of Underwriters Laboratories, Inc. Standard 1059, Guide No. XCFR2, File No. E62557. Guide No. 184-N-90, Report No. LR39186-1. Type CDM Terminal Designation CDM brass terminal bar with two No 10-32 washer-head screws acceptig wire up to No 10AWG Rated 30A Type CDM Dimensions NOTE mm dim. are shown in parentheses O.D. M.D. Marking Strip Number of Terminals Mounting Dimensions Inches Metric mm When ordering combinations of both types, the model number is made up of both model designations followed by total number of poles and number of each type .A composite of three H terminals followed by two BT terminals thus is converted to stock number HBT-5 3H, 2BT Number of Terminals Mounting Dimensions Inches Metric mm 4 108 4 124 5 141 6 157 6 174 7 190 8 207 8 223 9 240 10 256 10 273 11 289 12 306 12 322 13 339 14 355 14 372 15 388 15 405 16 421 17 438 17 454 18 471 19 487 19 504 20 520 Dimensions shown are ± 0 Overall Dimensions Inches Metric mm 4 109 4 126 5 142 6 159 6 175 7 192 When ordering combinations of both types, the composite number is made up of both model designations followed by total number of poles and number of each type A composite of two T terminals followed by two U terminals thus is converted to stock number TU-4 2T, 2U Combining these types with types L, O, S, H and BT would follow the same ordering format Note When combined with types H or BT, a special adapter is required Number of Terminals Mounting Dimensions Inches Metric mm 4 114 5 143 6 173 7 202 Dimensions shown are ± 0 Overall Dimensions Inches Metric mm 5 127 6 156 7 185 8 215 Types T & U Terminal Dimensions O.D. M.D. x Lg. Mtg. Holes x NOTE Lugs are not funished with blocks mm dim. are shown in parentheses BARRIER STYLE Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents Types T & U Accessories COVERS Types T and U Plain cover of 1/16" thick bakelite is permanently positioned to block with two screws Factory-assembled or customer-installed To order, specify T Part No 268A157 1 thru 6 terminals U Part No 268A157 1 thru 4 terminals Curtis Industries A Division of Powers Holdings, Inc. 1-800-657-0853 49 High Voltage/Current Types L, O & S L 1 29 .46mm , O 1 47 .24mm , TYPE L TYPE O Features: • Heavy Load Termination Flexibility Designed for machine, switchboard and other heavy load terminations • Readily Adaptable to Special Applications Can be used for branch circuit termination with simple modification of standard terminal plate • Combined Style Design Capability All types can be combined with each other as well as with Types H and BT • Ratings and Wire Sizes to Match High Current Needs Type L is rated at 100A/600V, UL recognized for wire up to No 1AWG Type O is rated 125A/600, UL recognized for wire up to No 1/0AWG Type S is rated 225A/600V, UL recognized for wire up to No 4/0AWG Note UL requires the use of UL recognized lugs • Recognition and Listing UL recognized and CSA certified TERMINAL DESIGNATIONS L Nickel-plated brass terminal bar with 1/4" 20 plated round-head steel screws Accepts wire up to No 1AWG O Nickel-plated brass terminal bar with 5/16" 18 plated slotted hex-head steel screws Accepts wire up to No 1/0AWG S Nickel-plated brass terminal bar with 3/8" plated hex-head steel screws Accepts wire up to No 4/0AWG When ordering combinations of both types, the model number is made up of both series designations followed by total number of poles and number of each type A model number of two L terminals followed by two O terminals thus is converted to stock number LO-4 2L, 2O Combining these types with types T, U, S, H and BT would follow the same ordering format Note When combined with types H or BT, a special adapter is required Type L Number of Terminals Mounting Dimensions Inches Metric mm Overall Dimensions Inches Metric mm 2 55 2 68 3 84 3 97 4 114 5 127 5 143 6 156 6 173 7 185 7 202 8 215 9 232 9 244 10 261 10 274 11 290 11 303 10 12 320 13 332 11 13 349 14 362 12 14 379 15 391 Type O Number of Terminals 1 2 3 4 Mounting Dimensions Inches Metric mm 4 120 6 167 8 214 Overall Dimensions Inches Metric mm 5 132 7 180 8 227 Type S Number of Terminals Mounting Dimensions Inches Metric mm Relay socket assemblies can be ordered in parts form assemblies and track separate or factory assembled in specific length units. When ordering factory assembled units, specify type number of sockets in continuous one-piece precut track for example, order RS8-17 for a track containing 17 RS8 relay socket assemblies. * Many Curtis Socket Assemblies are recognized under the Components Program of Underwriters Laboratories, Inc. under file No. E59934. These units are maked with a on the following pages. Socket Assemblies listed by Canadian Standards Association are marked with a and are covered by Report No. LR19623. Curtis Industries A Division of Powers Holdings, Inc. Specifications subject to change. Dimensions are shown for reference purposes only. CUS Series CUS8 8-Pin Unitized Octal-Type Socket Assemblies Specifications: Rating 10 amps, 300 volts Track TR2 48" length holds up to 30 CUS8 sockets Terminals 6 thru 32 with captivated traveling nut Wire Up to No. 12AWG wire Sockets CUS8 8-pin receptacle for 2PDT octal relay or timer 69,85 69,85 Dia. Mtg. Hole Slot 7,937 3456 73,0 11,1 23,0 34,9 36,49 7812 Typ. 3,175 33,27 39,62 4,76 15,9 TR2 Track 33,27 CUS5, CUS12 and CUS16 5, 8 and 11-Pin Unitized Square-Base Relay-Type Socket Assemblies Specifications: Rating 15 amps, 250 volts CSA rated 15 amps, 125 volts Track TR3 48" length holds up to 28 sockets Terminals 6 thru 32 with captivated traveling nut Wire Up to No. 14AWG wire Sockets CUS12 11-pin receptable for 3PDT square-base barrier-type plug-in relays CUS16 8-pin receptacle for 2PDT square-base, barrier type plug-in relays CUS5 5-pin receptacle for SPDT square-base, barrier type plug-in relays Mtg. 43,18 49,98 8,89 36,57 |
More datasheets: 2PSWTC | 2PDSWTC | 2PDSWSP | 2PSWSP | 2PDWT | 3PDSWSP | 3PDSWS | RS2 | CUS12 | RS12 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived CUS8 Datasheet file may be downloaded here without warranties.