PM22 Series
Part | Datasheet |
---|---|
![]() |
PM2260D50VJ (pdf) |
Related Parts | Information |
---|---|
![]() |
PM2260A95VRJH |
![]() |
PM2260A95VRH |
![]() |
PM2260D25V |
![]() |
PM2260D50V |
![]() |
PM2260D95VRJH |
![]() |
PM2260D95VJ |
![]() |
PM2260D95VH |
![]() |
PM2260D95VR |
![]() |
PM2260D95VJH |
![]() |
PM2260D95VRJ |
![]() |
PM2260A95V |
![]() |
PM2260D95VRH |
![]() |
PM2260A95VJ |
![]() |
PM2260A95VH |
![]() |
PM2260A95VR |
![]() |
PM2260A95VJH |
![]() |
PM2260A95VRJ |
![]() |
PM2260D95V |
![]() |
PM2260D25VJ |
![]() |
PM2260A25V |
![]() |
PM2260A50VRJ |
![]() |
PM2260D25VH |
![]() |
PM2260A50VJH |
![]() |
PM2260D25VR |
![]() |
PM2260A50VRJH |
![]() |
PM2260D50VRJH |
![]() |
PM2260A50VH |
![]() |
PM2260D25VJH |
![]() |
PM2260A50V |
![]() |
PM2260D50VRH |
![]() |
PM2260A50VJ |
![]() |
PM2260D25VRJ |
![]() |
PM2260A50VR |
![]() |
PM2260D50VR |
![]() |
PM2260A25VRJ |
![]() |
PM2260A25VRJH |
![]() |
PM2260D50VJH |
![]() |
PM2260D50VRJ |
![]() |
PM2260A25VRH |
![]() |
PM2260D25VRH |
![]() |
PM2260A25VJH |
![]() |
PM2260A25VH |
![]() |
PM2260D25VRJH |
![]() |
PM2260A25VJ |
![]() |
PM2260A50VRH |
![]() |
PM2260D50VH |
![]() |
PM2260A25VR |
PDF Datasheet Preview |
---|
DataSPanhel eMoeuntt PM22 Series Panel Mount SSRs • Output ratings up to 95 Amps at 600VAC • Built-in overvoltage protection • DBC substrate for superior thermal performance • LED input status indicator • IP20 touch-safe housing • AC or DC control • 4000 VAC optical isolation • C-UL-US and TUV approved PRODUCT SELECTION Control Voltage 90-280 VAC/VDC 4-32 VDC PM2260A25V PM2260D25V PM2260A50V PM2260D50V PM2260A95V PM2260D95V AVAILABLE OPTIONS Series PM22 Operating Voltage 60 48-600 VAC Rated Load Current 25 Amps 50 Amps 95 Amps [High I2t] 25 UV Switching Type Blank Zero Voltage Turn-On R Instantaneous Turn-On Motor Rating Certified Thermal Pad Blank Not Included H Included R J UH Required for valid part number For options only and not required for valid part number Control Voltage 1 A 90-280 VAC/VDC D 4-32 VDC Terminal Layout Input Connector V Contactor Configuration Blank Screw Terminal J Spring Terminal OUTPUT SPECIFICATIONS 2 Operating Voltage 47-440Hz [VRMS] Transient Overvoltage [Vpk] 3 Maximum Off-State Leakage Current Rated Voltage [mARMS] Minimum Off-State dV/dt Maximum Rated Voltage [V/usec] Load Current, General Use UL508/LC A IEC 62314 40°C [ARMS] 4 Load Current, Motor Starting UL508 FLA/LC B IEC 62314 40°C [ARMS] 4 Minimum Load Current [mARMS] Maximum 1 Cycle Surge Current 50/60Hz [Apk] Maximum On-State Voltage Drop Rated Current [Vpk] Thermal Resistance Juntion to Case Rjc [°C/W] Maximum 1/2 Cycle t for Fusing 50/60Hz sec] Minimum Heat Sink for Rated Current 40ºC [°C/W] Minimum Power Factor at Maximum Load Motor Rating UL 508/IEC62314 [HP kW ] 120 VAC Motor Rating UL 508/IEC62314 [HP kW ] 240 VAC Motor Rating UL 508/IEC62314 [HP kW ] 480 VAC 48-600 1200 1 500 25 100 286/300 409/375 2 3 48-600 1200 1 500 50 100 716/750 2563/2343 1 3 5 48-600 1200 1 500 95 26/14 150 1290/1350 8320/7593 2 5 10 INPUT SPECIFICATIONS 2 PM2260DxxV 4-32 VDC 5 -32 VDC 4 VDC 1 VDC 10 mA 15 mA Current Limited 1/2 Cycle 7 1/2 Cycle PM2260AxxV 90-280 VAC/VDC 6 - 90 VAC/VDC 5 VAC/VDC 6 mA 10 mA Current Limited |
More datasheets: PM2260D95V | PM2260D25VJ | PM2260A25V | PM2260A50VRJ | PM2260D25VH | PM2260A50VJH | PM2260D25VR | PM2260A50VRJH | PM2260D50VRJH | PM2260A50VH |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived PM2260D50VJ Datasheet file may be downloaded here without warranties.