mm DIN rail mounting MURc3 Part number 88826503

Relay or solid state output Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator relay version Option of connecting an external power supply to the control input 3-wire sensor control option

Type 88 826 105 MUR1 88 826 115 MAR1 88 826 125 MBR1 88 826 135 MCR1 88 826 145 MHR1 88 826 155 MLR1 88 826 100 MUR4 88 826 103 MUR3 88 826 503 MURc3 88 826 185 MXR1 88 826 004 MUS2 88 826 014 MAS5 88 826 044 MHS2 88 826 054 MLS2

Functions A - At - B - C- H - Ht - Di - D - Ac - Bw A - At B C H - Ht Li-L A - At - B - C - H - Ht - Di - D - Ac - Bw A - At - B - C - H - Ht-Di - D - Ac - Bw A - At - B - C - H - Ht - Di - D - Ac - Bw Ad - Ah - N - O - P - Pt - Tl - Tt - W A - At - B - C - H - Ht - Di - D - Ac - Bw A H Li - L

Timing

Output 1 changeover relay 1 changeover relay 1 changeover relay 1 changeover relay 1 changeover relay 1 changeover relay 1 changeover relay 1 changeover relay 1 changeover relay 1 changeover relay Solid state Solid state Solid state Solid state

Nominal rating 8A 0,7 A 0,7 A 0,7 A 0,7 A

Connections Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Spring terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals

Supply voltage 24 V DC / 24 V AC 24 V DC / 24 V AC 24 V DC / 24 V AC 24 V DC / 24 V AC 24 V DC / 24 V AC 24 V DC / 24 V AC 12 V AC / DC V AC/DC 12 V AC / DC 24 V DC / 24 V AC 24 V AC 24 V AC / DC 24 V AC 24 V AC

Timing ranges 7 ranges

Repetition accuracy with constant parameters Drift Temperature Drift Voltage Display accuracy according to IEC/EN 1812-1 Minimum pulse duration typically relay version Minimum pulse duration typically solid state version Minimum pulse duration typically relay version under load Maximum reset time by de-energisation typically relay version Maximum reset time by de-energisation typically solid state version Immunity from micro power cuts typical Supply Multi-voltage power supply Frequency Hz Operating range

Operator factor Max. absorbed power

Output specification 1 or 2 changeover relays, AgNi cadmium-free Rated power Maximum breaking current Minimum breaking current Voltage breaking capacity Electrical life operations Mechanical life operations Breakdown voltage acc. to IEC/EN 61812-1 Impulse voltage acc. to IEC/EN 60664-1, IEC/EN 61812-1 Solid state output Rated power

Derating Maximum admissible current Minimum breaking current Leakage current
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h TK2R1 0.6s - 2.5s - 20s - 160 s ± % IEC/EN 1812-1 ± 0,05 % / °C ± % / V ± 10 % / 25 °C 30 ms 50 ms
100 ms
100 ms
350 ms
> 10 ms

Depending on version 50 / 60 85 to 110 % Un 85 to 120 % Un for 12V AC/DC 100 % 0,6 W 24 V AC/DC 1,5 W 230 V AC 32 VA 230 V AC
2000 VA/80 W 2000 VA/80 W 8 A AC 8A DC 10 mA / 5 V DC 250 V AC/ DC 10 5 operations 8 A 250 V resistive 5x106 kV /1 min / 1 mA / 50 Hz 5 kV, wave / 50 us
0,7 A AC/DC 20 °C 0,5 A UL 5 mA / °C 20 A 10 ms 10 mA < 5 mA

Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
24/07/2012

Voltage breaking capacity Maximum voltage drop at terminals Electrical life operations

Mechanical life operations

Breakdown voltage acc. to IEC/EN 60664-1, IEC 60255-5 Input type
250 V AC/ DC 3 wire 4V - 2 wire 8V 108 kV to 1 mA / 1 min Volt-free contact 3-wire PNP output control option residual voltage 0.4V whatever the timer power supply

General characteristics

Conformity to standards

IEC/EN 61812-1

IEC/EN 61000-6-1 IEC/EN 61000-6-2 IEC/EN 61000-6-3 IEC/EN 61000-6-4

Certifications

CE, UL, cUL, CSA, GL

Temperature limits use °C

Temperature limits stored °C

Installation category acc. to IEC/EN 60664-1

Voltage surge category

Creepage distance and clearance acc. to IEC/EN 60664-1 4 kV / 3

Protection IEC/EN 60529