Type 84 870 204 ENR

Characteristics Monitoring filling UPMonitoring emptying DOWN

Specifications

Operating range Maximum power consumption Adjustable sensitivity Measurement accuracy at maximum sensitivity Electrode voltage max Electrode current maximum cable capacity Response time high level Response time low level Output relay according to AC1 resistive load Galvanic isolation via transformer 4 kV, 8 mm creepage distance Isolation of contacts and electrodes from power supply Operating temperature range °C Storage temperature range °C Weight g
x Un 3 VA 5 kΩ ± 30 % 24 V AC 50/60 Hz 1 mA 50/60 Hz 10 nF 300 ms 500 ms 1 AgNi changeover relay 8 A AC max.

Class II
kV AC -20 °C -40 °C 150

Principles

Voltages 230 V AC

Operating principle Monitoring maximum and/or minimum levels of conductive liquids tap water, sea water, waste water, chemical solutions, coffee, etc . The principle is based on measuring the apparent resistance of the liquid between two submerged probes. When this value is lower than the preset threshold displayed on the unit's front panel, the output relay changes state. To prevent any occurrences of electrolysis, an AC current is passed through the probes. Areas of application include the agri-food, chemical and other industries.

Adjusting two levels Minimum/Maximum The output relay changes state when the level of liquid reaches the maximum electrode, with the minimum electrode submerged. It returns to its initial state when the minimum probe is no longer in contact with the liquid.

Note If the power break T lasts for 1 second or more, the relay reenergises instantly when in "UP" mode and is de-energised when in "DOWN" mode.

Legend

Maximum level

Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
10/04/2014

Minimum level Output relay Down or Up

Dimensions mm ENR

Connections ENR

A1-A2 power supply

Legend
*** TRADUCTION MANQUANTE ***

Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
More datasheets: CGA0603MLA-22500E | CGA0603MLA-22101E | CGA0603MLA-22161E | CGA0603MLA-31900E | CGA0603MLA-32120E | CGA0603MLA-26800E | BCM8705BIFBG | VRE3050KS | VRE3050AS | VRE3050CS


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 84870204 Datasheet file may be downloaded here without warranties.

Datasheet ID: 84870204 507085