ED S SC 1

ED S SC 1 Datasheet


ED Domes and EDM Domes

Part Datasheet
ED S SC 1 ED S SC 1 ED S SC 1 (pdf)
Related Parts Information
EDM 450 G AC EDM 450 G AC EDM 450 G AC
EDM 650 G AC EDM 650 G AC EDM 650 G AC
EDM 450 G SC EDM 450 G SC EDM 450 G SC
ED S AC 1 ED S AC 1 ED S AC 1
ED S AC 0 ED S AC 0 ED S AC 0
ED G AC 1 ED G AC 1 ED G AC 1
EDM 450 S AC EDM 450 S AC EDM 450 S AC
ED G SC 0 ED G SC 0 ED G SC 0
ED S SC 0 ED S SC 0 ED S SC 0
ED G SC 1 ED G SC 1 ED G SC 1
EDM 450 S SC0 EDM 450 S SC0 EDM 450 S SC0
ED G AC 0 ED G AC 0 ED G AC 0
PDF Datasheet Preview
ED Domes and EDM Domes

ED, the disc contact is a momentary tact switch with short travel and good tactile feedback. Direct mounting on a printed circuit board is possible.

In that case, the dome must be actuated by a soft actuator of mm minimum diameter. The ED dome is available in various types of modules and is the main component of several switches presented in this catalog.

Self-cleaning system The contact is made on at least 3 points of the lower diaphragm, these 3 points of contacts are always different at each new switch action. During the switching movement, the upper disc slides on the lower diaphragm, ensuring the contact’s self-cleaning.

The EDM is available in 4 versions EDM 450 AU EDM 650 AU EDM 450 AG EDM 650 AG

The EDM Multi Dome Series was developed for low applications needing increased tactile response and high performance

Applications range from aircraft instrument panels to radio keypads. This high performance dome switch combines our reliable ED contact system with added tactile domes for forces of 4.5N 450 grams and 6.5N 650 grams .

Main features

Gold Au or silver Ag contacts Two different operating forces Low Compact PWB spacing Proven application in avionics

Construction

Function Contact arrangement Distance between button Terminals

Momentary 1 make contact = SPST PC pins or tabs

Momentary 1 make contact=SPST,NO centers, min. PC pins or tabs

Electrical data

Silver

Gold

Switching power max. AC/DC

Switching voltage max. AC/DC
100 V
100 V
100 V DC

Switching current max. AC/DC
100 mA
50 mA
50 mA

Carrying current max. AC/DC
250 mA
250 mA

Dielectric strength 50 Hz/1 Min. 300 V
300 V
300 V

Operating life with max. switching 106 operations 5 106 operations power

Contact resistance

Insulation resistance 100 V
1011
1011
1011

Contact bounce
100 µs
100 µs

Mechanical data Switching travel
Ordering code see next page. A-36

Dimensions are shown in mm inch Dimensions subject to change

Dimensional Drawings ED Domes

ED Domes and EDM Domes

Switch action principal

The disc contact is essentially made of two separate conductive domes diaphragms separated by an insulated material. The upper diaphragm is shaped so that under pressure it collapses suddenly and establishes contact with the lower diaphragm.

Upper diaphragm

Pressure

Lower diaphragm SWITCH IN RESTING POSITION

Insulating washer

Circular contact area

SWITCH IN ACTIVE POSITION
Ordering code 1 Designation ED / EDM450 / EDM650 2 Contact material S = silver, G = gold 3 Contacts AC = with PC pins, SC = with tabs 4 Sealing 0 = sealed, 1 = totally sealed

A-37

Example ED

Dimensions are shown in mm inch Dimensions subject to change
More datasheets: EDM 450 G AC | EDM 650 G AC | EDM 450 G SC | ED S AC 1 | ED S AC 0 | ED G AC 1 | EDM 450 S AC | ED G SC 0 | ED S SC 0 | ED G SC 1


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived ED S SC 1 Datasheet file may be downloaded here without warranties.

Datasheet ID: ED S SC 1 522488