BXRA-C0360-00E00

BXRA-C0360-00E00 Datasheet


The base product part number BXRA-ABCDE is indicated on each individual unit, printed on the bottom of the LED Array.

Part Datasheet
BXRA-C0360-00E00 BXRA-C0360-00E00 BXRA-C0360-00E00 (pdf)
Related Parts Information
BXRA-W0260-00Q00 BXRA-W0260-00Q00 BXRA-W0260-00Q00
BXRA-C0361-00E00 BXRA-C0361-00E00 BXRA-C0361-00E00
BXRA-W0261-00Q00 BXRA-W0261-00Q00 BXRA-W0261-00Q00
BXRA-W0241-00Q00 BXRA-W0241-00Q00 BXRA-W0241-00Q00
BXRA-W0240-00Q00 BXRA-W0240-00Q00 BXRA-W0240-00Q00
PDF Datasheet Preview
Bridgelux LS Array Series

Introduction

The Bridgelux family of LED Array products delivers high performance, compact and cost-effective solidstate lighting solutions to serve the general lighting market. These products combine the higher efficacy, lifetime, and reliability benefits of LEDs with the light output levels of many conventional lighting sources. The Bridgelux LS Array Series has been specified to enable lamp and luminaire designs which are thermally limited to a maximum of 4-8 Watts, including replacement lamps, decorative lighting and white goods applications.

The Bridgelux LS Array Series provides a high performance alternative to conventional solid state solutions, delivering between 240 and 360 lumens under application conditions in warm and cool white color temperatures. These compact high flux density light sources deliver uniform high quality illumination without pixilation or the multiple shadow effect caused by LED component based solutions, enabling both diffuse and directional lamp replacements for a wide range of applications. To simplify system design for appropriate light output, Bridgelux LED Arrays are specified to deliver performance under typical use conditions.

These integrated plug and play solutions reduce system complexity and enable miniaturized costeffective lamp and luminaire designs. Lighting system designs incorporating these LED Arrays deliver performance comparable to that of a 20-40 Watt incandescent, 20-35 Watt halogen and low wattage compact fluorescent lamps and luminaires and feature increased system level efficacy and service life. Typical applications include replacement lamps, task lighting, under cabinet, accent, pendant, sconces, porch, pathway, landscape, portable, and consumer luminaires and white goods.
• Compact high flux density light source
• Uniform high quality illumination
• Streamlined thermal path
• Energy Star / ANSI compliant binning
structure
• More energy efficient than
incandescent, halogen and fluorescent lamps
• Low voltage DC operation
• Instant light with unlimited dimming
• Long operating life
• RoHS compliant and Pb free
• Enhanced optical control
• Clean white light without pixilation
• Significantly reduced thermal resistance
and increased operating temperatures
• Uniform consistent white light
• Lower operating costs
• Increased safety
• Easy to use with daylight and motion
detectors to enable increased energy savings
• Reduced maintenance costs
• Environmentally friendly, no disposal issue
1170 Sonora Ct, Sunnyvale, CA 94086
• Tel 408 990-7500
• Fax 408 990-7501


Table of Contents Product Nomenclature Average Lumen Maintenance Characteristics Environmental Compliance UL Recognition Minor Product Change Policy Cautionary Statements Case Temperature Measurement Point Flux Characteristics Optical Characteristics Electrical Characteristics Absolute Minimum and Maximum Ratings Typical Performance at Alternative Drive Currents Mechanical Dimensions Typical Radiation Pattern Wavelength Characteristics Typical Relative Luminous Flux vs. Current Typical Light Output Characteristics vs. Temperature Typical Chromaticity Characteristics vs. Temperature Typical Forward Current Characteristics Current Derating Curves Product Binning Luminous Flux Binning Information Color Binning Information Mechanical Assembly and Handling Product Packaging and Labeling Packaging Tube Design Resources

Bridgelux LS Array Series Product Data Sheet DS14 01/26/09

Page 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 20 21 23 24 27 28

Page 2 of 29

Product Nomenclature

The part number designation for Bridgelux LED Arrays is explained as follows:

Where:

B X R A designates product family

A designates color, C for Cool White and W for Warm White

B C D designates LED Array product flux, 024 for a 240 lumen array, 026 for a 260 lumen array and 036 for a 360 lumen array

E designates product family

R used to designate product options, by default

The base product part number BXRA-ABCDE is indicated on each individual unit, printed on the bottom of the LED Array.

Average Lumen Maintenance Characteristics

Bridgelux projects that its family of LED Array products will deliver, on average, greater than 70% lumen maintenance after 50,000 hours of operation at the rated forward test current. This performance assumes constant current operation with case temperature maintained at or below 70°C. For use beyond these typical operating conditions please consult your Bridgelux sales representative for further assistance.

These projections are based on a combination of package test data, semiconductor chip reliability data, a fundamental understanding of package related degradation mechanisms, and performance observed from products installed in the field using Bridgelux die technology. Bridgelux conducts lumen maintenance tests per LM80. Observation of design limits is required in order to achieve this projected lumen maintenance.

Environmental Compliance

Bridgelux is committed to providing environmentally friendly products to the solid-state lighting market. Bridgelux LED Arrays are compliant to the European Union directives on the restriction of hazardous substances in electronic equipment, namely the RoHS directive. Bridgelux will not intentionally add the following restricted materials to LED Array products lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls PBB or polybrominated diphenyl ethers PBDE .

Bridgelux LS Array Series Product Data Sheet DS14 01/26/09

Page 3 of 29

UL Recognition

Bridgelux is in the process of securing UL Recognition for the LED Array products. This process is expected to be complete in February Bridgelux uses UL Recognized materials with suitable flammability ratings in the LED Array to streamline the process for customers to secure UL listing of the final luminaire product. Bridgelux recommends that luminaires are designed with a Class 2 Driver to facilitate the UL listing process.

Minor Product Change Policy

The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization.

CAUTION CONTACT WITH OPTICAL AREA

Contact with the resin area should be avoided. Applying stress to the resin area can result in damage to the product.

CAUTION EYE SAFETY

Eye safety classification for the use of Bridgelux LED Arrays is contained in the CIE S 009/E2002 Photobiological Safety of Lamps and Lamp Systems specification. Bridgelux LED Arrays are classified under section 6 lamp classification as Risk Group 2 Moderate Risk . Please use appropriate precautions. It is important that employees working with LEDs are trained to use them safely. Luminaire manufacturers should refer to CIE S 009/E2002 to establish the classification of their product.

CAUTION RISK OF BURN
More datasheets: PVT1028 BK005 | PVT1028 BK001 | FSTU6800WMX | FSTU6800QSCX | FSTU6800MTC | FSTU6800MTCX | BXRA-W0260-00Q00 | BXRA-C0361-00E00 | BXRA-W0261-00Q00 | BXRA-W0241-00Q00


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived BXRA-C0360-00E00 Datasheet file may be downloaded here without warranties.