MJSD0903
Part | Datasheet |
---|---|
![]() |
MJS 4 (pdf) |
Related Parts | Information |
---|---|
![]() |
MJS 500 |
![]() |
MJS 3.5 |
![]() |
MJS 125 |
![]() |
MJS 150 |
![]() |
MJS 200 |
![]() |
MJS 250 |
![]() |
MJS 300 |
![]() |
MJS 5 |
![]() |
MJS 400 |
![]() |
MJS 100 |
![]() |
MJS 750 |
![]() |
MJS 1 |
![]() |
MJS 1.25 |
![]() |
MJS 1.5 |
![]() |
MJS 2 |
![]() |
MJS 2.5 |
![]() |
MJS 3 |
![]() |
MJS 350 |
![]() |
MJS 7 |
![]() |
MJS 6 |
PDF Datasheet Preview |
---|
MJSD0903 Type MJS Lightning Surge Withstand Fuse 5 x 15mm Glass Tube MJS Fuses are primarily intended for use in telecommunication circuit applications requiring low current protection with high surge tolerance. They are typically used to replace heat coil type devices. They are designed to be placed between the line input and the surge arresting components mov, gas tube, zenor diode, air gaps, etc. These fuses will withstand transient surge currents generated by lightning in accordance with the attached table. MJS fuses guard protected circuitry against sustained overload or short circuit conditions. Such sustained overloads may be generated by accidental contact between utility cables and phone lines power line cross . MJS Fuses are used in circuits to obtain compliance with the test requirements specified in UL 1950/60950 and Bellcore Electrical Characteristics UL/CSA STD.248-14 Testing Current 100% 135% 200% 500% 1000% Blow Time Minimum Maximum 4 Hrs. 3 sec 20 sec 100 msec 30 msec 300 msec Approvals Vßpc Safety Agency Approvals V Listed File no. E20624 ß Certified File no. LR39772 p File no. JET1037-31003-1003 Amp range / Volt I.R. ability 100mA.- 7A / 125V 10,000A 100mA.- 7A / 250V 200A 1A.- 5A / 125V 500A mCatalog Number MJS 100 Ampere Rating 100mA Typical Cold Resistance ohm Volt-drop In Volt max. Melting I2T < 10 mSec A2 Sec Melting I2T In A2 Sec Peak Surge Current Amp Fig A fig B 25 Pulses 50 Pulses 10uS x 1000uS 10uS x 560uS Maximum Power Dissipation W ORDERING INFORMATION SEE PAGES 67 & 68 Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • E-Mail Website: Type MJS Lightning Surge Withstand Fuse 5 x 15mm Glass Tube MJS - TIME CURRENT CHARACTERISTIC CURVE MJSC0801 - 100mA - 125mA - 150mA - 200mA - 250mA - 350mA - 400mA - 500mA - 700mA - 750mA - 1A - 1.25A - 1.5A - 2A - 2.5A - 3A - 3.5A - 4A - 5A - 6A - 7A 10000 1000 TIME IN SECONDS Specifications subject to change without notice 1000 CURRENT IN AMPERES NOTE - see important information under “User Guide”on P.08 Corporate Office Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 E-Mail Website: Far East Office Bel Fuse Ltd. 8F/8 Luk Hop Street San Po Kong Kowloon, Hong Kong Tel 852-2328-5515 Fax 852-2352-3706 European Office Bel Fuse Europe Ltd. Preston Technology Management Centre Marsh Lane, Preston PR1 8UD Lancashire, U.K Tel 44-1772-556601 Fax 44-1772-888366 |
More datasheets: 70002416 | 70001615 | 70002415 | 70001613 | 70001614 | ECJ-CV50J106M | 1057 | A0750.LN | MJS 500 | MJS 3.5 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived MJS 4 Datasheet file may be downloaded here without warranties.