NFS110 Medical Series Single and quad output
Part | Datasheet |
---|---|
![]() |
NFS110-7915J (pdf) |
Related Parts | Information |
---|---|
![]() |
NFS110-7902PJ |
![]() |
NFS110-7912J |
![]() |
NFS110-7924J |
PDF Datasheet Preview |
---|
POWER Data Sheet NFS110 Medical Series Single and quad output Total Power 80 - 110 W Input Voltage 100 - 240Vac 127 - 357 Vdc # of Outputs Single, quad Special Features x inch package Medical, dental and laboratory applica- tions Overvoltage and short circuit protection 110 W with 20 CFM UL, cUL and VDE approvals EN60601-1 and UL2601 medical approvals Available RoHS compliant 2 years warranty Electrical Specifications Output Safety EN60950-1/IEC60950-1 EN60601-1 UL60601-1/CSA C22.2 No. 601-1 File No. E182560 Voltage adjustability: Line regulation Overshoot/undershoot Temperature coefficient: V o/p on multi’s V single output 12 V single output 15 V single output 24 V single output LL to HL, FL All outputs on all units At turn-on no lead All outputs ± ± 12 - 14 V 15 - 18 V 24 - 30 V ± max. 0% / °C Overvoltage protection: Multi o/p V only V single 12 V single 15 V single 24 V single V ± V ± V ± V 22 V ± V 33 V ± V Output power limit: Short circuit protection Input voltage range: Input frequency range Input surge current: Safety ground leakage current: Primary power limited 110 Vac. 50 Hz 230 Vac. 50 Hz 132 Vac 264 Vac Pin max. 160 W Pout min. 110 W Burst mode operation 100 - 240 Vac 127 - 357 Vdc 47 - 440 Hz 17 A 25 A 50 uA 100 uA All specifications are typical at nominal input, full load at 25 °C unless otherwise stated NFS110 Medical Series Data Sheet EMC Charateristics Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity: General Specifications Hold-up time: Efficiency: Ordering Information Output Voltage Output Currents Max 1 Peak 2 Fan 3 +12 V V IA +24 V IB 6 +12 V 20 A 9A 10 A 5A Ripple 4 50 mV 120 mV 120 mV 50 mV 50 mV 240 mV 120 mV 120 mV 120 mV 150 mV 240 mV Total Regulation 5 ± ± ± ± + + 10 / ± ± ± ± ± Model Numbers 13, 14, F NFS110-7901PJ NFS110-7902PJ NFS110-7912J 7,8 NFS110-7915J 7,8 NFS110-7924J 7,8 Transient Response NFS110-7901PJ V A 150 mV peak, 1 ms recovery +12 V A 100 mV peak, ms recovery -12 V A 100 mV peak, ms recovery -5 V A 100 mV peak, ms recovery NFS110-7902PJ V A 150 mV peak, 1 ms recovery +12 V A 100 mV peak, ms recovery -12 V A 100 mV peak, ms recovery 24 V A 300 mV peak,1 ms recovery NFS110-7905J V 10-20 A 250 mV peak, 1 ms recovery NFS110-7912J +12 V A 360 mV peak, 1 ms recovery NFS110-7915J +15 V A 450 mV peak, 1 ms recovery NFS110-7924J +24 V A 720 mV peak, 1 ms recovery Notes Convection cooled, 80 W maximum. Peak outputs lasting less than 60 seconds with duty cycle less than Total peak power must not exceed 110 W. Forced air, 20 CFM at 1 atmosphere, 110 W maximum. Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth using a 12 inch twisted pair terminated with a 47 uF capacitor. Total regulation is defined at the static output regulation at 25 °C, including initial tolerance, line voltage within stated limits and output voltages adjusted to their factory settings. Also for NFS110-7902PJ, for 24 V output stated regulation IA / This output will maintain regulation if 5 A, where IA = V output current and IB = +24 V output current. Single output models have floating outputs which may be referenced as either positive or negative. Higher voltage supplies, may be adjusted over a wide output voltage range, as long as the total output power does not exceed 80 Watts natural convection or 110 Watts forced air . Power fail detect not available on single output models. Derating curve is application specific for ambient temperatures > 50 °C, for optimum reliability no part of the heatsink should exceed 90 °C and no semiconductor case temperature should exceed 100 °C. Caution Allow a minimum of 1 second after disconnecting the power when making thermal measurements. The user should read the PSU installation instructions in conjunction with the relevant national safety regulations in order to ensure compliance. Three orthogonal axes, random vibration, 10 minute test for each axis. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. The ‘J’ suffix indicates that these parts are Pb-free RoHS 6/6 compliant. TSE RoHS 5/6 non Pb-free compliant versions may be available on special request, please contact your local sales representative for details. NOTICE Some models do not support all options. Please contact your local Artesyn Embedded Technologies representative or use the on-line model number search tool at to find a suitable alternative. NFS110 Medical Series Data Sheet AC J1 mating connector Molex 09-50-3051 or Molex 09-91-0500 mating connector with 2478 or equivalent crimp terminals. DC J2 mating connector Molex 09-50-3131 or Molex 09-91-1300 mating connector with 2478 or equivalent crimp terminals. OPTIONAL POWER FAIL DETECT TIMING DIAGRAM AC INPUT 4.75V 5V OUTPUT LOW PFD SIGNAL MAX 4.75V HIGH 3.5V MIN T3 T2 Power fail detect signal Note 8 50 ms T1 200 ms T2 will vary with line and load T3 3 ms Pout 110 W PFD output is an open collector which will sink 40 mA in the low state. TT11 Voltage Adjust Optional Power Fail Detect Circuit Key = Pin 2 |
More datasheets: 2875 | 63-NBM-A | 61-NBM-A | 62-NBM-A | CY22M1SCALGXI-00 | CY22M1LCALGXC-00 | CY22M1LCALGXI-00 | CY22M1SCALGXC-00 | PT2559B-F | NFS110-7902PJ |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived NFS110-7915J Datasheet file may be downloaded here without warranties.