Total Power 110-150 Watts Input Voltage 85-132 / 170-264 VAC
Part | Datasheet |
---|---|
![]() |
70-841-009 (pdf) |
PDF Datasheet Preview |
---|
150 Watts LPS150 Series Total Power 110-150 Watts Input Voltage 85-132 / 170-264 VAC 220-300 VDC # of Outputs Single Special Features • Auto ranging input • Remote sense • Remote inhibit • Power fail • Single wire current sharing • Built-in EMI filter • Low output ripple • Adjustable output • 135 khz switching frequency • Overvoltage protection • Overload protection • Optional cover -C suffix . Environmental Operating temperature 0° to 50°C ambient derate each output at per degree from 50° to 70°C Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5,-6, Level 3 Humidity Operating non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances G peak 5 Hz to 500 Hz, operational Storage temperature -40° to 85°C Temperature coefficient per °C MTBF demonstrated >550,000 hours at full load and 25°C ambient conditions Electrical Specs Input Input range Frequency Inrush current Efficiency EMI filter Safety ground leakage current 85-132 VAC or 170-264 VAC automatically selected. 220-300 VDC 47-63 Hz 38 A max, cold start 25°C 75% typical at full load FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted mA 50/60 Hz, 264 VAC input Output Maximum power Adjustment range Hold-up time Overload protection Overvoltage protection Logic Control Power Failure Remote inhibit Remote sense 110 W convection 75 W with cover 150 W with 30 CFM forced air 130 W with cover ±5% minimum 20 ms 110 W load, 115/230 VAC nominal line Short circuit protection. Case overload protected 110% to 145% above peak rating 5 V output to VDC. Other outputs 10% to 25% above nominal output TTL Logic signal goes high 50-150 msec after 5 V output. It goes low at least 3 ms before loss of regulation. Requires an external TTL high signal to inhibit outputs. Safety VDE UL CSA NEMKO BABT CB CE 0805/EN60950 IEC950 UL1950 CSA Level 3 EN 60950/EMKO-TUE 74-sec 203 EN60950/BS7002 Certificate and report Mark LVD 11774-3336-1260 LC#88585 EI32002 LR53982 P95102999 607019 2062 Ordering Information Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling LPS152 LPS153 12- 15 V LPS155 24- 28 V Maximum Load with 30 CFM Forced Air Peak Load1 Peak current lasting <30 seconds with a maximum 10% duty cycle. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a µF capacitor at rated line and load ranges. Note -C suffix added to the model number indicates cover option. Regulation2 Ripple P/P PARD 3 ±2% 50 mV ±2% 150 mV ±2% 280 mV, max. Connector SK1 PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 SK2 PIN 5 PIN 6 PIN 7 SK3 TB-1 TB-2 SK4 PIN 1 PIN 3 PIN 5 Pin Assignments LPS152 LPS153 LPS155 INHIBIT -ve INHIBIT +ve VCC No Connection COMMON -SENSE +SENSE C SHARE INHIBIT -ve INHIBIT +ve VCC No Connection COMMON -SENSE +SENSE C SHARE INHIBIT -ve INHIBIT +ve VCC No Connection COMMON -SENSE +SENSE C SHARE COMMON PIN REMOVED POK COMMON PIN REMOVED POK COMMON PIN REMOVED POK COMMON +5 V COMMON +12 to +15 V COMMON +24 to +28 V GROUND LINE NEUTRAL GROUND LINE NEUTRAL |
More datasheets: CTANK-M210 | CTANK-M210-12 | CTANK-M120 | CTANK-M120-12 | CTANK-M220 | CTANK-M220-12 | CTANK-M520 | CTANK-M520-12 | CTANK-A521 | CTANK-A620 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 70-841-009 Datasheet file may be downloaded here without warranties.