70-841-015

70-841-015 Datasheet


Astec connector kit #70-841-015, includes al of the above.

Part Datasheet
70-841-015 70-841-015 70-841-015 (pdf)
PDF Datasheet Preview
175 Watts

LPQ172 Series

Total Power 110-175 Watts Input Voltage 85-264 VAC
120-300 VDC # of Outputs Quad

Electrical Specs

Input

Input range Frequency Inrush current Efficiency EMI filter

Power factor Safety ground leakage current
85-264 VAC, 120-300 VDC 47-63 Hz 38 A max, cold start 25°C 75% typical at full load Meets FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted typical
mA 50/60 Hz, 264 VAC input

Special Features
• Active power factor correction
• IEC EN61000-3-2 compliance
• Adjustable outputs on 1, 3 & 4

Remote sense on main output
• Single wire current sharing
• Power fail and remote inhibit
• Built-in EMI filter
• Low output ripple
• Overvoltage protection
• Overload protection
• Thermal overload protection
• DC power good
• 5 V standby output
• Adjustable floating 4th output
• Optional cover -C suffix

Environmental

Operating temperature 0° to 50°C ambient
derate each output at per degree from
50° to 70°C except for -C version

Electromagnetic susceptibility designed to meet EN61000-4, -2, -3, -4, -5, -6, -8, -11, Level 3

Humidity Operating non-condensing
5% to 95%

Vibration Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances G peak 5 Hz to 500 Hz, operational

Storage temperature -40° to 85°C

Temperature coefficient ± per °C

MTBF demonstrated >550,000 hours at full load and 25°C ambient conditions

Output

Maximum power

Adjustment range Hold-up time Overload protection

Overvoltage protection Standby output

Logic Control

AC Power failure

Remote inhibit Remote sense

DC Ok
110 W convection 75 W with cover 175 W with 30 CFM forced air 130 W with cover - 5.5V on main -12 - 15V on 3rd output - 25 V on 4th output 20 ms W load at nominal line Short circuit protection on all outputs. Case overload protected 110-145% above peak rating Tracks outputs 1, 3 & 4 15 to 35% 5 V 200 mA regulated ±5%

VDE UL CB CSA CE NEMKO

Safety
0805/EN60950 IEC950 UL1950 Certificate and report CSA Level 3 Mark LVD EN 60950/EMKO-TUE

Americas 1-888-41-ASTEC

Europe UK 44 1384 842-211

Asia HK 852-2437-9662

AMERICAS
Ordering Information

Model Number

LPQ172

Output Voltage

Minimum Load
5 V - V 12 V -12 V -12 -15 V
0A A*

Maximum Load with Convection Cooling
15 A 6A A 2A

Maximum Load with 30 CFM Forced Air
30 A 8A 3A 5A

Peak Load
32 A 10 A

Regulation2
±2% ±3% ±3% ±3%

Ripple P/P PARD 3
50 mV 120 mV <1% <50mV or 1%

Peak current lasting <30 seconds with a maximum 10% duty cycle. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a µF capacitor at rated line voltage and load ranges. 4th output adjustable V factory set at 5 V. *Minimum loads are required when output set below 5 Volts Remote inhibit resets OVP latch

Note -C suffix added to the model number indicates cover option and is limited to 50C operation.

Pin Assignments

Connector LPQ172

PIN 1

PIN 2
5V Standby

PIN 3

PIN 4

V1 SWP

PIN 5

Common

PIN 6
+V1 sense

PIN 7

Sense common

PIN 8

Remote inhibit

PIN 9

DC power good

PIN 10

PIN 1,2 +12 V

PIN 3,4,5 Common

PIN 6
More datasheets: CWR-181-15-0021 | CWR-182-25-0021 | CWR-182-37-0000 | CWR-183-37-0000 | CWR-182-09-0021 | CWR-180-09-0021 | CWR-181-09-0021 | CWR-183-09-0021 | CWR-182-15-0003 | CWR-183-09-0000


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 70-841-015 Datasheet file may be downloaded here without warranties.

Datasheet ID: 70-841-015 518829