AP6C64AA

AP6C64AA Datasheet


AP6C64AA

Part Datasheet
AP6C64AA AP6C64AA AP6C64AA (pdf)
PDF Datasheet Preview
48V 400-600 Amp

Breaker Panel BIP

AP6C64AA

A breaker interface panel, also knows as a power distribution unit PDU , or frame supervisory panel FSP , improves system power stability and provides a convenient centralized location for all customer load circuit breakers, alarms, and filtering.

INPUT

AMERICAS
5810 Van Allen Way Carlsbad, CA 92008 Telephone 760-930-4600 Facsimile 760-930-0698

EUROPE

Astec House, Waterfront Business Park Merry Hill, Dudley

West Midlands, DY5 1LX, UK Telephone 44 1384 842-211 Facsimile 44 1384 843-355

ASIA

Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road

Fwai Fong, New Territories Hong Kong

Telephone 852-2437-9662 Facsimile 852-2402-4426

Electrical Specs

DC input
-40 VDC to VDC

Transients Input feeds

ANSI T1.315-1994, FTZ19, BTR2511
4 x 100A each 4 x 150A each available in the future

Special Features
• Low profile
• Fits in 2U height,
• mm
• 23" width
• 4 x 100 A input feeds, upgradeable to 4 x 150A
input feeds
• supports A & B redundant input feeds
• 4 hot swappable Breaker Modules + one Alarm

Module
• Breaker Modules available in various configurations,
all come equipped with
• 28,200 µF capacitor bank
• automatic inrush current limiting
• hot swappable, field replaceable without
service interruption
• Breaker Module configurations:
• 5A
• 20A
• 25A 5A 25A
• 10A 5A 30A 5A 10A
• 25A
• 30A 5A 30A
• other configurations available on request,
please consult your Astec representative
• Standard Alarm module comes equipped with:
• isolated alarm contacts
• input feed fail alarm
• output breaker trip alarm
• critical, major, minor alarms
• end aisle lamp drive
• fully programmable, 6 bit, shelf ID
• LED test switch
• connections for voice and data jacks
• Enhanced, customized alarm modules available by special order

OUTPUT

DC output

Alarm signals
20 x 25A breakers total Four breaker modules, each with 5 x 25A breakers

Critical, major, minor alarms

Environmental

EMC/EMI:

No switching components, inherently EMI/EMC benign

ESD:

Bellcore GR-1089-CORE, ETSI 300 386-1,
15kV
More datasheets: 96MPP4-3.4F8-2M7T1 | 13847 | 2222 085 67228 | 2222 085 63109 | 2222 085 63229 | 2222 085 65478 | 2222 085 65109 | 2222 085 66338 | 2222 085 67478 | 2222 085 68108


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived AP6C64AA Datasheet file may be downloaded here without warranties.

Datasheet ID: AP6C64AA 518813