120 Watts

AA20140 Series

Total Power 70-120 Watts Input Voltage 85-264 VAC # of Outputs Quad

Special Features
• Active power factor correction
• EN61000-3-2 compliance
• Remote sense on outputs one and two
• Industry-standard x 7” footprint
• Adjustable main outputs
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection
• Thermal overload protection

Environmental

Operating temperature 0° to 50°C ambient derate each output at per degree from 50° to 70°C Electromagnetic susceptibility Designed to meet EN61000-4, -2, -3, -4, -5, -6, Level 3 Humidity Operating non-condensing 20% to 90% Vibration 5-32 Hz sinewave double amplitude 32-2 kHz sinewave 1 G peak Storage temperature -40° to 85°C Temperature coefficient per °C MTBF per mil std 217E >200,000 hours at full load and 30°C ambient conditions and full load

Electrical Specs

Input

Input range Frequency Inrush current Efficiency EMI filter

Power factor Safety ground Leakage current

Output

Maximum power Adjustment range Hold-up time Overload protection

Overvoltage protection

Remote sense
90-264 VAC 47-63 Hz 40 A max., cold start 25°C 65% typical at full load FCC Class B conducted and radiated, CISPR 22 Class B conducted and radiated, EN55022 Class B conducted and radiated, VDE 0878 PT3 Class B conducted and radiated. typical
<2 mA 50/60 Hz, 254 VAC input
70 W convection 120 W with 30 CFM forced air ±5% minimum on V and 5 V outputs 15 ms 120 W load, 115 VAC input Short circuit protection on all outputs. Case overload protected 110-145% above peak rating V output V 5 V output V, 20-35% above nominal output. Latching type recycle AC to reset. Compensates for V lead drop min. Will operate without remote sense connected.

Safety

EN60950
9837006

UL1950

E186249

CSA Level 3

E186249

Certificate and report DE2-002056

Mark LVD
110044 America’s USA 1-888-41-ASTEC

Europe UK 44 1384 842-211 Asia HK 852-2437-9662

AA20140 Series

AMERICAS
5810 Van Allen Way Carlsbad, CA 92008 Telephone 760-930-4600 Facsimile 760-930-0698

EUROPE

Astec House, Waterfront Business Park Merry Hill, Dudley

West Midlands, DY5 1LX, UK Telephone 44 1384 842-211 Facsimile 44 1384 843-355

ASIA

Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road

Fwai Fong, New Territories Hong Kong

Telephone 852-2437-9662 Facsimile 852-2402-4426
Ordering Information

Model Number

Output Voltage

Minimum Load

Maximum Load with Convection Cooling

Maximum Load with 30 CFM Forced Air

Peak

Load

AA20140

V +5 V +12 V -12 V
0A 1A A 0A
8A 10 A 1A A

Peak current lasting <30 seconds with a maximum 10% duty cycle. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a µF capacitor at rated line voltage and load ranges. Minimum loads are required.

Regulation
±2% ±3% ±5% ±10%

Ripple

P/P PARD
50 mV 50 mV 120 mV 120 mV

Pin Assignments

Connector

PIN 1

Neutral

PIN 3

Live

PIN 1-10 Common

PIN 11
+5 Sense

PIN 12

V Sense

PIN 13
+12 V

PIN 14-17 5 V

PIN 18-22 V

PIN 23

Return Sense

PIN 24
-12 V

Mating Connectors SK1 AC Input:

Molex 09-50-8031 USA Molex 09-91-03500 UK PINS 08-58-0111

SK2 DC Output:

Molex Right angle 39-30-1240 or 39-29-1248 or Vertical 39-28-1243