Astec Connector Kit #70-841-014, includes all of the above
Part | Datasheet |
---|---|
![]() |
70-841-014 (pdf) |
Related Parts | Information |
---|---|
![]() |
NTQ162 |
![]() |
NTQ165 |
![]() |
NTQ163 |
PDF Datasheet Preview |
---|
50-165 Watts NTQ160 Series Total Power 50-165 Watts Input Voltage 85-264 VAC # of Outputs Quad Electrical Specs Input Input range Frequency Inrush current Efficiency EMI filter Power factor Safety ground leakage current 85-264 VAC 47-63 Hz 38 A max., cold start 25°C 65% typical at full load 115 VAC input FCC Class B conducted and radiated, CISPR 22 Class B conducted and radiated, EN55022 Class B conducted and radiated, VDE 0878 PT3 Class B conducted and radiated. typical <1 mA 50/60 Hz, 264 VAC input Special Features • Active power factor correction • EN61000-3-2 compliance • Remote sense on outputs one and two • Power fail and remote inhibit • 5V Standby output • DC Power good • Single wire current sharing on outputs one and two • Wide range adjustable on outputs 1 & 2 • Built-in Class B EMI filter • Overvoltage protection • Overload protection • Thermal overload protection • Outputs 3 & 4 are floating Environmental Operating temperature 0° to 50°C ambient derate each output at per degree from 50° to 70°C Electromagnetic susceptibility Designed to meet EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3 Output Maximum power Adjustment range Hold-up time Overload protection Overvoltage protection Standby output Logic Control Power failure Remote Inhibit Remote sense 50W convection, 165 W with 30 CFM forced air 1.8V - 3.5V 3.0V - 5.5V on outputs one and two 20 ms 165 W load Short circuit protection on all outputs. Case overload protected 110-145% above peak rating. Latching type recycle AC to reset. Tracks outputs 1 & 2 20% to 35% above output setting 2 A regulated ±5% Humidity Operating non-condensing 10% to 95% Safety Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances G peak 5 Hz to 500 Hz, operational Storage temperature -40° to 85°C Temperature coefficient ± per °C MTBF demonstrated >1 million hours at full load and 25°C ambient conditions UL CSA NEMKO BABT CB CE 0805/EN60950 IEC950 UL1950 CSA Level 3 EN 60950/EMKO-TUE 74-sec 203 EN60950/EN41003 Certificate and report Mark LVD 21310-3336-0021 129066 E186249 LR109492C P00100493 650251, NC/00069 9661, 9662, 8788 Support 888 41-ASTEC or 407 241-2752 Americas 760 930-4600 Europe UK 44 1384 842-211 Asia HK 852-2437-9662 AMERICAS Ordering Information Model Number NTQ162 Output Voltage V 1.8 - 3.5V +5 V 3 - 5.5V 12 V* 12 V* Minimum Load 2A 0A Maximum Load with Convection Cooling 15 A 10 A 2A Maximum Load with 30 CFM Forced Air 30 A 20 A Peak Load1 38 A 22 A 5A Regulation2 ±2% ±2% ±3% ±3% Ripple P/P PARD 3 50 mV 50 mV 120 mV 120 mV NTQ163 +5 V 3 - 5.5V V - 3.5V 0 A 12 V* 12 V* 30 A 20 A ±2% ±2% ±3% ±3% 50 mV 50 mV 120 mV 120 mV NTQ165 V 3 - 5.5V 2 A ±2% V - 3.5V 0 A ±2% ±3% 12 V* ±3% * outputs are floating Peak current lasting <30 seconds with a maximum 10% duty cycle. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a µF capacitor at rated line voltage and load ranges. Minimum loads are required. In parallel minimum loads are A on the V1 output and 1 A on the V2 output for each power supply. Total output current between V1 and V2 is 40A maximum. Ordering Information Connector PIN 1 PIN 3 PIN 5 Ground Neutral Live SK2 SK3 SK4 SK6 C91 SK3 D9 SK4 R41 C86 C84 VR2 VR1 SK2 C89 4321 C85 R78 THR3 THR2 C46 C43 THR4 L15 IC8 PIN 1 PIN 2 PIN 3 PIN 4 PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 PIN 9 PIN 10 Mating Connectors SK1 AC Input: SK2,3,4: V1 Common V2 V4 Common V4 V3 Common V3 V2 SWP 5V Standby +V2 Sense V1 SWP COMMON +V1 Sense COMMON Remote Inhibit DC Power Good Power Fail Molex 09-50-8051 USA Molex 09-91-0500 UK PINS 08-58-0111 Molex BB-124-08 L4 C34 HTSK-SEC1 Q1 HTSK-PRI1 L6 R27 |
More datasheets: U6820BM-MFP | 264-10UYT/S530-A3 | FST32X245QSPX | IPC-6806WP-35CE | IPC-6806P3-25DE | DM74ALS21AM | DM74ALS21AN | DM74ALS21AMX | NTQ162 | NTQ165 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 70-841-014 Datasheet file may be downloaded here without warranties.