NTQ123 Series
Part | Datasheet |
---|---|
![]() |
NTQ123 (pdf) |
PDF Datasheet Preview |
---|
70-120 Watts NTQ123 Series Total Power 70-120 Watts Input Voltage 85-264 VAC # of Outputs Quad Special Features • Active power factor correction • EN61000-3-2 compliance • Remote sense on outputs one and two • Power fail and remote inhibit • Single wire current sharing on outputs one and two • Adjustable main outputs • Built-in Class B EMI filter • Overvoltage protection • Overload protection • Thermal overload protection Environmental Operating temperature 0° to 50°C ambient derate each output at per degree from 50° to 70°C Electromagnetic susceptibility Designed to meet EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances G peak 5 Hz to 500 Hz, operational Storage temperature -40° to 85°C Temperature coefficient ± per °C MTBF demonstrated >1 million hours at full load and 25°C ambient conditions Electrical Specs Input Input range Frequency Inrush current Efficiency EMI filter Power factor Safety ground leakage current Output Maximum power Adjustment range Hold-up time Overload protection Overvoltage protection Logic Control Power failure Remote inhibit Remote sense 85-264 VAC 47-63 Hz 38 A max., cold start 25°C 65% typical at full load FCC Class B conducted and radiated, CISPR 22 Class B conducted and radiated, EN55022 Class B conducted and radiated, VDE 0878 PT3 Class B conducted and radiated. typical <1 mA 50/60 Hz, 264 VAC input 70 W convection, 120 W with 30 CFM forced air ±5% minimum on outputs one and two 20 ms 120 W load, 120 VAC input Short circuit protection on all outputs. Case overload protected 110-145% above peak rating V and 5 V output 20% to 35% above nominal output VDE UL CSA NEMKO BABT CB CE Safety 0805/EN60950 IEC950 21310-3336-0004 UL1950 E186249 CSA Level 3 LR109492C EN 60950/EMKO-TUE P98100870 74-sec 203 EN60950/EN41003 608497 Ordering Information Model Number Output Voltage Minimum Load4 Maximum Load with Convection Cooling Maximum Load with 30 CFM Forced Air Peak Load1 Regulation2 NTQ123 ±2% ±2% +12 V ±3% -12 V ±3% Peak current lasting <30 seconds with a maximum 10% duty cycle. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. Peak-to-peak with 20 MHz bandwidth and 10 uF in parallel with a uF capacitor at rated line voltage and load ranges. Minimum loads are required. In parallel minimum loads are A on the 5 V output and 1 A on the V output for each power supply. Ripple P/P PARD 3 50 mV 50 mV 120 mV 120 mV Pin Assignments Connector PIN 1 Ground PIN 3 Neutral PIN 5 Live PIN 1 +12 V PIN 2 Common PIN 3 -12 V PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 PIN 9 |
More datasheets: 892010T BK013 | 892010T RD001 | 74F779SC | 74F779PC | HDJD-JD07 | 1135 | FFP05U60DNTU | B39321R0961H110 | B39321R961H110 | 40222R |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived NTQ123 Datasheet file may be downloaded here without warranties.