PDF Datasheet Preview
Embedded Power for Business-Critical Continuity

NFS40 Series

SIngle and triple output

Total Power 40 - 50W Input Voltage 85 - 264 Vac
120 - 370 Vdc
# of Outputs Single, triple

Special Features
• x inch package 1U applications
• Industry standard package
• Overvoltage and
short circuit protection
• 40 W with free air convection
• 50 W with 20 CFM forced air
• EN55022, EN55011
conducted noise level B
• UL, VDE and CSA
safety approvals
• Available RoHS compliant
• 2 year warranty

Safety
• VDE0805/EN60950/
• IEC950/IEC1010
• File No. 10401-3336-0044
• License No. 2559
• UL1950 File No. E136005
• CSA C22.2 No. 950
• File No. LR41062C

Electrical Specifications

Input Voltage adjustability:

Line regulation LL to HL, FL Load regulation FL to NL Transient response:
+5 V output on triples Vout on singles

Main output Auxiliary outputs

Main output Auxiliary outputs
+5 V - 3 A

Temperature coefficient Overvoltage protection Output power limit Short circuit protection:

Output Input voltage range:

All outputs +5 V output Primary power limited Single outputs Multiple outputs

Universal input

Input frequency range Max. input surge current:

Safety ground leakage current:
132 Vac, cold start 264 Vac, cold star
110 Vac, 60 Hz 230 Vac, 50 Hz
± ± ± ± ± ± ± 120 mV max. dev. 500 µs recovery ± 0.02%/°C S3.15 A, 250 Vac In live and neutral 90 W input power limit Continuous Short term
85 - 264 Vac 120 - 370 Vdc 47-440 Hz 12 A max. 24 A max. mA, max. mA, max.

Embedded Power for Business-Critical Continuity

Specifications

All specifications are typical at nominal input, full load at 25 °C unless otherwise stated

EMC Charateristics 11, 12 Conducted emissions Radiated emissions ESD  air ESD contact Surge Fast transients Radiated immunity Conducted immunity:

EN55022, FCC part 15 EN55022 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-2, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3

Level B Level A Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 2 Perf. criteria 2

General Specifications

Hold-up time:
Ordering Information

Output Voltage

Max 1
+12 V B
+12 V B
-12 V C
+12 V B
+15 V B

Output Currents Peak 2 7A 3A 1A 7A 1A 7A 3A 1A 7A A 1A 12 A 12 A 5A 4A A

Fan 3 5A 2A A 5A A 5A 2A A 5A 2A A 8A 4A A 2A

Ripple 4
50 mV 120 mV 120 mV 120 mV 120 mV 50 mV 120 mV 50 mV 50 mV 150 mV 150 mV 100 mV 100 mV 120 mV 150 mV 240 mV

Total Regulation 5

Model Numbers 13, 14, F

NFS40-7608J 5,6
± ±

NFS40-7628J 12

NFS40-7607J 5,6

NFS40-7610J 5,6

NFS40-76S3J

NFS40-7605J

NFS40-7612J

NFS40-7615J

NFS40-7624J

Notes 1 Natural convection cooled, 40 W maximum. 2 Peak output current lasting less than 30 seconds with duty cycle less than

During peak loading, outputs may go outside of total regulation limits. Peak total power must not exceed 60 W. 3 Forced air, 20 CFM at 1 atmosphere, 50 W maximum. 4 Figure is peak-to-peak. Output noise is measured across a 50 MHz bandwidth using a 12 inch twisted pair, terminated with a 47 µF capacitor.
5 Total regulation is defined as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits, load currents within stated limits, and output voltages adjusted to their factory settings. Also, 0.25<I A / I B <5.0 to maintain stated regulation. This does not apply to the NFS40-7628J power supply as it has regulated auxiliary outputs. 6 A minimum load of A is required on the +5 V output to obtain full current from the negative output. 7 The NFS40 offers the possibility of power sharing between outputs. Consult factory for details.
8 Derating curve is application specific for ambient temperatures >50 °C, for
optimum reliability no part of the heatsink should exceed 110 oC and no semiconductor case temperature should exceed 115 oC. 9 A 4 W minimum load is recommended to achieve the design MTBF. 10 Caution Allow a minimum of 1 second after disconnecting the power when making thermal measurements. 11 Three orthogonal axes, sweep at 1 octave/minute, 5 minute dwell at four major resonances. 12 The NFS40-7628J has separately linear regulated +12 V and -12 V outputs. The loading conditions in Notes 5 and 6 do not apply. 13 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 14 The ‘J’ suffix indicates that these parts are Pb-free RoHS 6/6 compliant. 15 NOTICE Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search tool at to find a suitable alternative.

J1 Pin 1 Pin 2

J2 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 P1 c Pin 1

Pin Connections
-7608J, -7628J -7607J
-7610J

AC Live

AC Live

AC Live

AC Neutral AC Neutral AC Neutral

SINGLES AC Line AC Neutral
+12 V Return -12 V
More datasheets: 471-002 | NFS40-7605J | NFS40-7612J | NFS40-7608J | NFS40-7628J | NFS40-76S3J | NFS40-7610J | NFS40-7624J | NFS40-7610 | NFS40-7608


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived NFS40-7628 Datasheet file may be downloaded here without warranties.

Datasheet ID: NFS40-7628 518467