LPT80 Series
Part | Datasheet |
---|---|
![]() |
LPT82 (pdf) |
Related Parts | Information |
---|---|
![]() |
LPT83 |
![]() |
LPT81 |
![]() |
70-841-018 |
PDF Datasheet Preview |
---|
Embedded Power for Business-Critical Continuity LPT80 Series 80 Watts Total Power 55 - 85 Watts Input Voltage 85 - 264 Vac 120 - 370 Vdc # of Outputs Triple Special Features • Power Factor Correction • EN61000-3-2 compliant • Universal input • 3” x 5” footprint • Remote sense on outputs 1 & 2 for LPT81 • Power fail and remote inhibit • Wide range adjustable on outputs 1 & 2 for LPT81 • Built-in Class B EMI filter • Overvoltage protection • Overload protection Safety • VDE • UL • CSA • NEMKO • AUSTEL • CB • CE 60950 Certificate & report Mark LVD Electrical Specifications Input Input 85 - 264 Vac 120 - 300 Vdc Frequency: 47 - 440 Hz Inrush current: 18 A peak 115 Vac < 36 A peak 230 Vac, cold start 25 °C Input current: A max. RMS 115 Vac Efficiency: 75% typical at full load EMI filter: FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted Safety ground leakage current Output Maximum power: < 1 mA 50/60 Hz, 264 Vac input 60 W for convection LPT81, 55 W 85 W with 30 CFM forced air Adjustment range: V - V on outputs one and two V - V for LPT81 Hold-up time: 20 ms 85 W load, 115 Vac nominal line Overload protection Short circuit protection on all outputs. Case overload protected 145% above peak rating Overvoltage protection Tracks outputs 1 & 2 for LPT81 20% to 35% above output setting Embedded Power for Business-Critical Continuity Logic Control Power failure Remote inhibit Remote sense: logic signal goes high 100 - 500 msec after V1 output It goes low at least 4 msec before loss of regulation Requires contact closure to inhibit outputs Environmental Specifications Operating temperature 0° to 50 °C ambient derate each output at per degree from 50° to 70 °C Temperature coefficient ± per °C Ordering Information Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling Maximum Load with 30CFM Forced Air Peak Load 1 Regulation 2 LPT81 V - V A ±2% +5 V - V ±2% +12 V LPT82 +5 V - V A 13 A ±5% ±2% +12 V ±5% LPT83 -12 V +5 V - V A 13 A ±5% ±2% +15 V ±5% -15 V ±5% Peak current lasting < 30 seconds with a maximum 10% duty cycle. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a µF capacitor at rated line voltage and load ranges. Minimum loads are required Total current of all outputs can not exceed 21 A. Ripple P/P PARD 3 50 mV 50 mV 120 mV 50 mV 120 mV 120 mV 50 mV 150 mV 150 mV Embedded Power for Business-Critical Continuity Mechanical Drawing 4x Ø 1 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone +1 760 930 4600 Facsimile +1 760 930 0698 Europe UK Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone +44 0 1384 842 211 Facsimile +44 0 1384 843 355 Asia HK 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone +852 2176 3333 Facsimile +852 2176 3888 |
More datasheets: SLB1240R45 | SLB1340R45 | SLB124145 | SLB1470 | SLB1280R5 | SLB1470R | SLB12804 | SLB12814 | SLB1370R | LPT83 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived LPT82 Datasheet file may be downloaded here without warranties.