LPT82

LPT82 Datasheet


LPT80 Series

Part Datasheet
LPT82 LPT82 LPT82 (pdf)
Related Parts Information
LPT83 LPT83 LPT83
LPT81 LPT81 LPT81
70-841-018 70-841-018 70-841-018
PDF Datasheet Preview
Embedded Power for Business-Critical Continuity

LPT80 Series
80 Watts

Total Power 55 - 85 Watts Input Voltage 85 - 264 Vac 120 - 370 Vdc # of Outputs Triple

Special Features
• Power Factor Correction
• EN61000-3-2 compliant
• Universal input
• 3” x 5” footprint
• Remote sense on outputs 1
& 2 for LPT81
• Power fail and remote inhibit
• Wide range adjustable on
outputs 1 & 2 for LPT81
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection

Safety
• VDE
• UL
• CSA
• NEMKO
• AUSTEL
• CB
• CE
60950 Certificate & report Mark LVD

Electrical Specifications

Input

Input
85 - 264 Vac 120 - 300 Vdc

Frequency:
47 - 440 Hz

Inrush current:
18 A peak 115 Vac < 36 A peak 230 Vac, cold start 25 °C

Input current:

A max. RMS 115 Vac

Efficiency:
75% typical at full load

EMI filter:

FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted

Safety ground leakage current Output Maximum power:
< 1 mA 50/60 Hz, 264 Vac input
60 W for convection LPT81, 55 W 85 W with 30 CFM forced air

Adjustment range:

V - V on outputs one and two V - V for LPT81

Hold-up time:
20 ms 85 W load, 115 Vac nominal line

Overload protection Short circuit protection on all outputs. Case overload protected 145% above peak rating

Overvoltage protection Tracks outputs 1 & 2 for LPT81 20% to 35% above output setting

Embedded Power for Business-Critical Continuity

Logic Control Power failure Remote inhibit Remote sense:
logic signal goes high 100 - 500 msec after V1 output It goes low at least 4 msec before loss of regulation

Requires contact closure to inhibit outputs

Environmental Specifications

Operating temperature 0° to 50 °C ambient derate each output at per degree from 50° to 70 °C

Temperature coefficient ± per °C
Ordering Information

Model Number

Output Voltage

Minimum Load

Maximum Load with Convection Cooling

Maximum Load with 30CFM Forced Air

Peak Load 1

Regulation 2

LPT81 V - V A
±2%
+5 V - V
±2%
+12 V LPT82 +5 V - V

A 13 A
±5%
±2%
+12 V
±5%

LPT83
-12 V +5 V - V

A 13 A
±5%
±2%
+15 V
±5%
-15 V
±5%

Peak current lasting < 30 seconds with a maximum 10% duty cycle.

At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.

Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a µF capacitor at rated line voltage and load ranges.

Minimum loads are required Total current of all outputs can not exceed 21 A.

Ripple P/P PARD 3
50 mV 50 mV 120 mV 50 mV 120 mV 120 mV 50 mV 150 mV 150 mV

Embedded Power for Business-Critical Continuity

Mechanical Drawing
4x Ø 1
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone +1 760 930 4600 Facsimile +1 760 930 0698

Europe UK

Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone +44 0 1384 842 211 Facsimile +44 0 1384 843 355

Asia HK
14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone +852 2176 3333 Facsimile +852 2176 3888
More datasheets: SLB1240R45 | SLB1340R45 | SLB124145 | SLB1470 | SLB1280R5 | SLB1470R | SLB12804 | SLB12814 | SLB1370R | LPT83


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived LPT82 Datasheet file may be downloaded here without warranties.

Datasheet ID: LPT82 518456