EXA40-48S05

EXA40-48S05 Datasheet


EXA40 Series

Part Datasheet
EXA40-48S05 EXA40-48S05 EXA40-48S05 (pdf)
Related Parts Information
EXA40-24S3V3-V EXA40-24S3V3-V EXA40-24S3V3-V
EXA40-48S2V75-V EXA40-48S2V75-V EXA40-48S2V75-V
EXA40-24S1V8S EXA40-24S1V8S EXA40-24S1V8S
EXA40-48S1V8-V EXA40-48S1V8-V EXA40-48S1V8-V
EXA40-24S2V75-V EXA40-24S2V75-V EXA40-24S2V75-V
PDF Datasheet Preview
EXA40 Series

Single output

DC/DC CONVERTERS 40W High Efficiency DC/DC Converters
• High efficiency topology, 91% typical at 5V
• Approved to EN60950, UL1950, CSA C22.2 No. 234/950
• Operating ambient temperature of -40°C to +70°C
natural convection
• Complies with ETS 300 019-1-3/2-3
• Complies with ETS 300 132-2 input voltage and current
requirements
• Fully compliant with ETS 300 386-1

The EXA40 Series, comprising 8 different models is targeted specifically at the telecommunications, industrial electronics, mobile Telecommunications and distributed power markets. The series offers two wide input voltage ranges of 18-36VDC and 36-75VDC. Typical efficiencies are 91% for the 5V output, 88% for the 3.3V, 86% for the 2.75V and 84% for the 1.8V. The series has been designed primarily for Telecommunications applications and complies with ETS 300 386-1 immunity and emission standards for high priority of service class. In addition the series complies with ETS 300 019-1-3 environmental standards all classes including shock, vibration, humidity and thermal performance. A high level of reliability has been designed into all models through the extensive use of conservative derating criteria. Remote enable and overtemperature shutdown are included as standard while true latching OVP is available as an option.

All specifications are typical at nominal input, full load at 25°C unless otherwise stated
2 YEAR WARRANTY

SPECIFICATIONS

OUTPUT SPECIFICATIONS Voltage adjustability

Line regulation Load regulation Output current range Ripple and noise

Temperature coefficient OVP transient See Note 6

OVP latching See Notes 1, 3 optional

Short circuit protection Note 5 Short circuit current Note 5 Transient response Peak deviation Settling time Current limit Voltage accuracy
2V75, 3V3, 5V outputs 1V8 output

Low line to high line

Full load to no load
20MHz bandwidth 20MHz bandwidth

See Figure 4
5V output 3V3/2V75 outputs 1V8 output
5V output 3V3 output 2V75 output 1V8 output

Continuous Rshort
50% to 75% and back to no external cap

Low line to high line

MINIMUM ±10% +12/-17%
6.0V 4.0V 3.4V 2.4V
100%

INPUT SPECIFICATIONS

Input voltage range
24Vin nominal 48Vin nominal

Input current

No load Remote OFF, UVLO

Inrush current

ETS 300 132-2

UVLO turn ON voltage Note 4 All inputs UVLO turn OFF voltage Note 4 All inputs

Start-up time

Nominal line

MINIMUM 18VDC 36VDC
88% 77%

TYPICAL