Embedded Power for Business-Critical Continuity

NLP110 Series

Single and Triple Output

Total Power Input Voltage # of Outputs:
80-110 Watts 90-264 VAC Single, Triple

Special Features
• Provides low voltage outputs
• Compliance to EN61000-3-2

Power Factor =
• 90 Vac to 264 Vac universal
input range
• UL, CSA and VDE safety
approvals and CE-Marked to LVD
• Overvoltage and short circuit protection
• VDE0871-B, EN55022-B, EN55011-B conducted noise
• VDE0871-A, EN55022-A, EN55011-A radiated noise
• Meets all applicable and relevant immunity standards EN61000-4-2,4,5 and 6
• RoHS compliant
• 2 year warranty

Safety
• VDE0805/EN60950/IEC950 File No. 10401-3336-1096
• UL1950 File No. E136005
• CSA C22.2 No. 950 File No. LR41062
• CCC Mark

Electrical Specifications

Input

Frequency Input surge current cold start Safety ground leakage current Input current:

Input fuse Output Total regulation line and load Rise time Transient response:

Temperature coefficient Overvoltage protection Short circuit protection Minimum output current:

Universal input See Note 6
120 Vac 230 Vac 120 Vac, 60 Hz 230 Vac, 50 Hz 120 Vac 80 W 120 Vac 110 W 230 Vac 80 W 230 Vac 110 W UL/IEC127

Main output Auxiliary outputs At turn-on Main output 75% to 100% step at A µs

Main outputs Cyclic operation Single and multiple
90-264 Vac
47-63 Hz 18 A max. 35 A max. mA A rms A rms A rms A rms F3.15A H, 250 Vac
s, max.
or 250 mV max. dev., 1 ms max. recovery to 1% ±0.02%/°C 125%, ±10%

Continuous

See table

All specifications are typical at nominal input, full load at 25 °C unless otherwise stated.

Embedded Power for Business-Critical Continuity

EMC Characteristics

Conducted emissions:

EN55022, FCC part 15 Level B

Radiated emissions:

EN55022, FCC part 15

Harmonic current emission correction EN61000-3-2

Level A Compliant

ESD air:

EN61000-4-2
Ordering Information

Output Voltage
+5 V +12 V +48 V +24 V +5 V A V B +12 V A V B +12 V +12 V A V B -12 V +12 V A +5 V B -12 V

Min 6

A 0A A 0A A 0A A 0A A 0A

Max 1
15 A 13 A 13 A 13 A 13 A 13 A 13 A
150 LFM 2
22 A 16 A 16 A 1A 16 A 16 A 1A A 16 A 1A A 16 A 1A
300 LFM 3
22 A 18 A 20 A 1A 20 A 20 A 1A A 20 A 1A A 18 A 1A

Peak 4
22 A 18 A 20 A
1A 22 A 22 A 1A 10 A 22 A 1A 10 A 22 A 1A

Ripple 5
50 mV 120 mV 240 mV 240 mV 50 mV 50 mV 120 mV 50 mV 50 mV 120 mV 120 mV 50 mV 120 mV 120 mV 50 mV 120 mV

Total Regulation
± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ±

Model Numbers 7, 14, 15 NLP110-9605J NLP110-9612J NLP110-9617J NLP110-9624J NLP110-9693J

NLP110-9694J

NLP110-9695J

NLP110-9608J

Notes 1 Free air convection.

Multiple output units maximum continuous output power not to exceed 80 W. For -9693J I3.3 V = 13 A max. I5.0 V = 13 A max. I3.3 V + I5.0 V 16 A. For -9694J I3.3 V = 13 A max. I2.5 V = 13 A max. I3.3 V + I2.5 V 16 A For -9695J I3.3 V = 13 A max. I12 V = A max. I3.3 V + I12 V 16 A. For -9608J I5.0 V = 13 A max. I12 V = A max. I5.0 V + I12 V 16 A. Single output units maximum continuous output power not to exceed 75 W on -9905J W on -9912J,-9924J, and -9917J. 2 150 LFM forced air cooling from L4 side. Multiple output units maximum continuous output power not to exceed 105 W. For -9693J I3.3 V = 16 A max. I5.0 V = 16 A max. I3.3 V + I5.0 V 20 A. For -9694J I3.3 V = 16 A max. I2.5 V = 16 A max. I3.3 V + I2.5 V 20 A For -9695J I3.3 V = 16 A max. I12 V = A max. I3.3 V + I12 V 20 A. For -9608J I5.0 V = 16 A max. I12 V = A max. I5.0 V + I12 V 20 A. Single output units maximum continuous output power not to exceed 110 W for all models. 3 300 LFM forced air cooling from L4 side. Multiple output units maximum continuous output power not to exceed 110 W. For -9693J I3.3 V = 20 A max. I5.0 V = 18 A max. I3.3 V + I5.0 V 22 A. For -9694J I3.3 V = 20 A max. I2.5 V = 20 A max. I3.3 V + I2.5 V 22 A For -9695J I3.3 V = 20 A max. I12 V = A max. I3.3 V + I12 V 22 A. For -9608J I5.0 V = 20 A max. I12 V = A max. I5.0 V + I12 V 22 A. Single output units maximum continuous output power not to exceed 110 W for all models. 4 Peak output current lasting less than 30 seconds with duty cycle less than During peak loading, output voltage may exceed total regulation limits. 5 Figure is peak-to-peak for convection power rating. Output noise measurements are made across a 20 MHz bandwidth using a 6’ twisted pair, terminated with a 10 µF electrolytic capacitor and a µF ceramic capacitor. 6 Minimum load required for correct start-up and operation on single outputs and on main output of multiple versions. Failure to observe minimum load on main output will not allow the supply to start-up correctly. Some electronic test loads have a large delay time before they start drawing current even though the voltage from the supply is present. During this time delay, there is no load on the output and as a result, the supply cannot startup properly and maintain its correct output voltage. In these instances, a dummy resistive load across the output may be necessary to load the output of the supply until the test load can function correctly and draw the intended minimum load. Minimum load required on auxiliary outputs to maintain regulation.
7 For models NLP110-9608J and NLP110-9695J, the 12 V output is floating. For -12 V output, pin 11 on J2 has to be connected to Return making pin 12 the -12 V output
8 Three orthogonal axes, random vibration 10 minutes for each axes, G rms 5 Hz to 500 Hz.
9 For optimum reliability, no part of the heatsink should exceed 110 and no semiconductor case temperature should exceed 120
10 CAUTION Allow a minimum of 1 second after disconnecting line power when making thermal measurements.
11 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product.
12 The EMI specifications reference measurements made with the power supply mounted on a grounded metal sheet extending 1 inch beyond each edge, using an unshielded cable. No external filtering required during conducted emissions testing but some applications may require additional filtering to achieve system compliance. A line choke, ac input cords looped twice through an EMI suppression toroid was used during radiated emissions testing. Considerable radiated testing in 1U six-sided boxes has shown that units can meet level B in typical systems. Application support is available from the factory to assist with EMI compliance.
13 All models require a minimum mounting stand-off of mm inches in the end use product.
14 The ‘J’ suffix indicates that these parts are Pb-free RoHS 6/6 compliant.
15 NOTICE Some models do not support all options. Please contact your local

Emerson Network Power representative or use the on-line model number
search tool at

Embedded Power for Business-Critical Continuity

T1 REF.

ALL DIMENSIONS IN INCHES mm

MAXIMUM COMPONENT HEIGHT IS

Recommended direction
for forced air relative to