AS73210-AS89010-C3 SET DK

AS73210-AS89010-C3 SET DK Datasheet


Coverpage AS73210-AS89010-C3 SET DK User Guide

Part Datasheet
AS73210-AS89010-C3 SET DK AS73210-AS89010-C3 SET DK AS73210-AS89010-C3 SET DK (pdf)
PDF Datasheet Preview
high performance needs great design.

Coverpage AS73210-AS89010-C3 SET DK User Guide

Please be patient while we transfer this adapted former MAZeT document to the latest ams design.

User Guide

DN[Document ID]

AS73210AS89010-C3 SET DK

Development Kit with USB interface
ams User Guide [v1-00] 2017-Jul-11

Page 1 Document Feedback

AS73210-AS89010-C3 SET DK Development Kit with USB interface

Content Guide

Introduction 3

Scope of Delivery 4

System 6

Specification of C3 SET DK 6

Start-up, Installation & Updates 7

Sensor Software Interface & C3 7

Software 8

Repair & 8

Software 9

Startup Configuration 9

Initialization 9

Main User Interface 11

Menu 13

Sensor Settings 14

Get PWM Period 16

Measurement 18

Color Patch 20

Calibration 21

Quick Start 26

Example for Measurement 27

Troubleshooting 29

Out of Range 29

Measurement Timeout 29

Known Software Messages & 30

Mechanical Sizes 31

Software License Agreement 32

Reference Documents 32
Ordering Information 32

Contact 33

Copyrights & 34
ams User Guide [v1-00] 2017-Jul-11

Page 2 Document Feedback

AS73210-AS89010-C3 SET DK Development Kit with USB interface
1 Introduction

The SET DK AS73210-AS89010-C3 Development Kits includes the AS73210-AS89010-C3 OEM sensor board optional embedded into a metallic casing with optical components and test software.

During this document the AS73210-AS89010-C3 will further on be referred to as "C3".

The main components of the system and its installation and usage are described within this document. The Set DK C3 is delivered without pre-calibration. So it is not specified for an application but was prepared for a user specific calibration as application specific setting and calibration of the system. That can be performed via known XYZ targets or similar within the application or via parallel connected spectrometer, spectral photometer, densitometer or other devices for color measurement and XYZ output The user calibrations can be saved in the sensor within the EEPROM of the C3 for the various applications. Data g and evaluation options can be used for testing and analysis. The C3 SET DK was designed as a test system under laboratory conditions it is intended to be used for system and application tests in applications for color measurement and control.

Figure 1 Block diagram OEM Sensor board C3

The OEM sensor board C3 [4] is a small PCB for general color measurement and control applications, with a high bandwidth of light y designed for in-line and handheld applications. The sensor board includes the True Color sensor AS73210 [2] XYZ sensor based on the international CIE 1931 standard human eye perception , a special analog-to-digital converter AS89010EQ [1] with a high dynamic range 1-to-1,000,000 , power supply, a µC with EEPROM for sensor data, an integrated temperature sensor and an USB interface. USB is used for external communication, configuration of the sensor, readout of the sensor data as well as writing and reading of the memory. The standard software is only designed for Windows based systems Windows 7 and above . For Window based customer test software ams Sensors Germany will offer a C3 Library. All links to the reference documents are located at the last section of this document. The following chapters describe the Development Kit and especially the software setup and usage for Windows PCs. Please make sure to install all libraries and the test software before connecting the Development Kit to a computer via USB.
ams User Guide [v1-00] 2017-Jul-11

Page 3 Document Feedback

AS73210-AS89010-C3 SET DK Development Kit with USB interface
2 Scope of Delivery

The C3 product family includes alternative delivery forms with the following standard elements One or more sensor board s SET DK C3 Documentation datasheet and more on USB stick Setup for PC test software, driver and Compiler Runtime on USB stick USB cable original <3 m Optional C3 Library and optical parts

For the scope of delivery of alternatives see the following table:

Table 1 Scope of delivery for C3 product family

Name

C3 Sensor Board with USB-Interface

C3 SET DK Development Kit with USB-Interface

Article Type of delivery

Sensor-IC AS73210 Signal converter AS89010EQ USB interface Firmware µP-programmed

Bootloader inside C3 Library PC Windows Test software Sensor metallic package with optical aperture

USB cable Suitcase for components
2207900021 Plastic cases in carton

O 2 Order# E0O82Z000847 O ---2 ---
-----
220790004 Suitcase with inserted
components
1 Please note, the color sensor is a PCB without package. So sensor handling precautions should be observed to avoid static discharge. 2 Optional, must be ordered separately.
ams User Guide [v1-00] 2017-Jul-11

Page 4 Document Feedback

AS73210-AS89010-C3 SET DK Development Kit with USB interface

The housed test system consists from a basic case which will be adapted customized and/or application specific by various parts and optical components apertures .

The solid basic case was made of anodized aluminum, which protects the sensor board C3 against mechanical stress as well as ESD and EMF. The sensor AS73210 is positioned in the basic case coaxial with a 3/8”-24 UNF internal thread and ready for the application of different optical accessories.

Table 2 Basic case and adapters for the DK

C3JCDK-Basic case

JCDK-Aperture-13.5

JCDK-Aperture-13.5 with IR-cut-off filter
13 Ordering Information

NAME C3 SET DK

JCDK-Aperture-13.5 with IR-cut-off filter JCDK-1/4“-Adapter JCDK-SMA-Adapter

Status Development Kit Accessories

Accessories

Article 220790004 on request
on request on request

The Development Kits and OEM modules described here are only to be used for compatibility-, qualification tests, and verification procedures or as risks. They are not designed to be used in series products.

Please note, the OEM sensors and kits were designed to be a test system for usage in laboratories only. They are not suitable for outdoor applications or to as series devices for inline measurements. Do not use the device in any process control or in any other series applications!

Before using engineering samples for anything other than system tests, please ask our sales team for status and availability of series or customized system solutions.
ams User Guide [v1-00] 2017-Jul-11

Page 32 Document Feedback

AS73210-AS89010-C3 SET DK Development Kit with USB interface
14 Contact Information

Buy our products or get free samples online at:

Technical Support is available at:

Provide feedback about this document at:

For further information and requests, e-mail us at:

For sales offices, distributors and representatives, please visit:

Headquarters ams AG Tobelbader Strasse 30 8141 Premstaetten Austria, Europe

Tel +43 0 3136 500 0 Website:
ams User Guide [v1-00] 2017-Jul-11

Page 33 Document Feedback

AS73210-AS89010-C3 SET DK Development Kit with USB interface
15 Copyrights & Disclaimer

Copyright ams AG, Tobelbader Strasse 30, 8141 Premstaetten, Austria-Europe. Trademarks Registered. All rights reserved. The material herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner.

Information in this document is believed to be accurate and reliable. However, ams AG does not give any representations or warranties, expressed or implied, as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information.

Applications that are described herein are for illustrative purposes only. ams AG makes no representation or warranty that such applications will be appropriate for the specified use without further testing or modification. ams AG takes no responsibility for the design, operation and testing of the applications and end-products as well as assistance with the applications or end-product designs when using ams AG products. ams AG is not liable for the suitability and fit of ams AG products in applications and end-products planned.
ams AG shall not be liable to recipient or any third party for any damages, including but not limited to personal injury, property damage, loss of profits, loss of use, interruption of business or indirect, special, incidental or consequential damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical data or applications described herein. No obligation or liability to recipient or any third party shall arise or flow out of ams AG rendering of technical or other services.
ams AG reserves the right to change information in this document at any time and without notice.
ams User Guide [v1-00] 2017-Jul-11

Page 34 Document Feedback

AS73210-AS89010-C3 SET DK Development Kit with USB interface
ams User Guide [v1-00] 2017-Jul-11

Page 35 Document Feedback
More datasheets: 26-21UYC/S530-A3/TR8 | PI74AVC164245A | FSES0765RGWDTU | M43106 WH001 | M43106 WH005 | M43106 WH002 | DP 21 | DP 31A | DP 52 | 76002052


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived AS73210-AS89010-C3 SET DK Datasheet file may be downloaded here without warranties.