Scotchlok Terminals

MU18-6FFB thru MU10-10FFB

Flanged Block Fork, Non-Insulated, Butted Seam

Data Sheet

Wire

Product Range Stud

Barrel

Number AWG Size W

E Thickness Length I.D.

MU18-6FFB 22-18 6

MU18-8FFB 22-18 8

MU18-10FFB 22-18 10

MU14-6FFB 16-14 6

MU14-8FFB 16-14 8

MU14-10FFB 16-14 10

MU10-6FFB 12-10 6

MU10-8FFB 12-10 8

MU10-10FFB 12-10

LISTED 314R

UNDERWRITERS LABORATORIES STANDARD NO. UL 486A 3M FILE NO. E23438

Specifications

Wire Size Barrel Seam Max. Current Terminal Material Plating:

CANADIAN STANDARDS ASSOCIATION STANDARD NO. C22.2 NO. 65 3M FILE NO. LR22190

See Table Above Butted Same as Wire ETP Copper Tin

Installation Information

WARNING

Turn power off before installing or removing terminal. All electrical work should be done according to appropriate electrical codes.

UL Listed and CSA Certified for use on stranded copper AWG wire only. Strip away the end 3/8 inch of wire insulation. Make the crimp in the proper station of a recommended 3M crimp tool TH-440, TH-450 scissor style , or TR-490 ratchet style hand tools.

Barrel Crimp Electrical

Engineering Specification

Crimp-type terminals shall, electrically and mechanically, connect to a pre-stripped end of a stranded copper wire and have a flat tongue portion with a central opening for mounting around a screw or stud.

The terminal line shall offer tongue variations in hole stud size 6, 8 10, etc. and configuration ring, fork, block fork, flanged block fork, locking fork, etc. and barrel variations in wire AWG size 22-18, 16-14, 12-10, etc. and construction non-insulated brazed seam, vinyl insulated butted seam, nylon insulated with insulation grip, etc. . The terminal line shall have regulatory agency coverage UL Listing, CSA Certification . The terminal tongue shall be marked with the wire range and manufacturer’s symbol

The non-insulated, butted seam flanged block fork terminal shall be tin-plated, annealed copper, with the tongue having a specified stud slot size 6 thru 10 and a butted seam barrel with a beveled I.D. for ease of stranded wire entry, sized for a specified AWG wire range 22-18, 16-14,

Non-insulated terminals shall be UL Listed and CSA Certified.
3M and Scotchlok are trademarks of 3M

IMPORTANT NOTICE Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use.

Warranty Limited Remedy Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted.

Electrical Products Division
6801 River Place Blvd. Austin, TX 78726-9000

Litho in USA. 3M 2002 78-8126-0488-8-A
More datasheets: 8406-CM | 8406BK-DCM | 8408BK-DCM | 8408BK-CM | 8406BK-TS | 8406BK-TM | 8406BK-CM | 8406-DCM | MU10-8FFBK | MU18-6FFBK


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived MU10-6FFBK Datasheet file may be downloaded here without warranties.

Datasheet ID: MU10-6FFBK 520938